Electron beam damage of perfluorosulfonic acid studied by soft X-ray spectromicroscopy.

Micron

Dept. Chemistry and Chemical Biology, McMaster University, Hamilton, ON, L8S4M1, Canada.

Published: June 2019

Scanning transmission X-ray microscopy (STXM) was used to study chemical changes to perfluorosulfonic acid (PFSA) spun cast thin films as a function of dose imparted by exposure of a 200 kV electron beam in a Transmission Electron Microscope (TEM). The relationship between electron beam fluence and absorbed dose was calibrated using a modified version of a protocol based on the positive to negative lithography transition in PMMA [Leontowich et al, J. Synchrotron Rad. 19 (2012) 976]. STXM was used to characterize and quantify the chemical changes caused by electron irradiation of PFSA under several different conditions. The critical dose for CF-CF amorphization was used to explore the effects of the sample environment on electron beam damage. Use of a silicon nitride substrate was found to increase the CF-CF amorphization critical dose by ∼x2 from that for free-standing PFSA films. Freestanding PFSA and PMMA films were damaged by 200 kV electrons at ∼100 K and then the damage was measured by STXM at 300 K (RT). The lithography cross-over dose for PMMA was found to be ∼2x higher when the PMMA thin film was electron irradiated at 120 K rather than at 300 K. The critical dose for CF-CF amorphization in PFSA irradiated at 120 K followed by warming and delayed measurement by STXM at 300 K was found to be ∼2x larger than at 300 K. To place these results in the context of the use of electron microscopy to study PFSA ionomer in fuel cell systems, an exposure of 300 e/nm at 300 K (which corresponds to an absorbed dose of ∼20 MGy) amorphizes ∼10% of the CF-CF bonds in PFSA. At this dose level, the spatial resolution for TEM imaging of PFSA is limited to 3.5 nm by radiation damage, if one is using a direct electron detector with DQE = 1. This work recommends caution about 2D and 3D morphological information of PFSA materials based on TEM studies which use fluences higher than 300 e/nm.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.micron.2019.02.006DOI Listing

Publication Analysis

Top Keywords

electron beam
16
critical dose
12
cf-cf amorphization
12
electron
9
pfsa
9
beam damage
8
perfluorosulfonic acid
8
chemical changes
8
dose
8
absorbed dose
8

Similar Publications

Influence of Photoemission Geometry on Timing and Efficiency in 4D Ultrafast Electron Microscopy.

Chemphyschem

January 2025

University of Minnesota Twin Cities, Chemical Engineering and Materials Science, 421 Washington Avenue SE, 55455, Minneapolis, UNITED STATES OF AMERICA.

Broader adoption of 4D ultrafast electron microscopy (UEM) for the study of chemical, materials, and quantum systems is being driven by development of new instruments as well as continuous improvement and characterization of existing technologies. Perhaps owing to the still-high barrier to entry, the full range of capabilities of laser-driven 4D UEM instruments has yet to be established, particularly when operated at extremely low beam currents (~fA). Accordingly, with an eye on beam stability, we have conducted particle tracing simulations of unconventional off-axis photoemission geometries in a UEM equipped with a thermionic-emission gun.

View Article and Find Full Text PDF

Atom probe tomography (APT) enables three-dimensional chemical mapping with near-atomic scale resolution. However, this method requires precise sample preparation, which is typically achieved using a focused ion beam (FIB) microscope. As the ion beam induces some degree of damage to the sample, it is necessary to apply a protective layer over the region of interest (ROI).

View Article and Find Full Text PDF

The challenge of imaging low-density objects in an electron microscope without causing beam damage is significant in modern transmission electron microscopy. This is especially true for life science imaging, where the sample, rather than the instrument, still determines the resolution limit. Here, we explore whether we have to accept this or can progress further in this area.

View Article and Find Full Text PDF

Volume electron microscopy (vEM) enables biologists to visualize nanoscale 3D ultrastructure of entire eukaryotic cells and tissues prepared by heavy atom staining and plastic embedding. The highest resolution vEM technique is focused ion-beam scanning electron microscopy (FIB-SEM), which provides nearly isotropic (~5-10 nm) spatial resolution at fluences of > 10,000 e /nm . However, it is not clear how such high resolution is achievable because serial block-face (SBF) SEM, which incorporates an in-situ ultramicrotome instead of a Ga FIB beam, results in radiation-induced collapse of similar specimen blocks at fluences of only ~20 e /nm .

View Article and Find Full Text PDF

In this study, minced turkey meat samples were subjected to electron-beam irradiation with dosages of 0, 1.5, 3, and 5 kGy, and then microbial (mesophilic and psychrotrophic bacteria), physiochemical (pH, water activity [a], thiobarbituric acid reactive substances [TBARS], and peroxide value [PV]), and sensory (color, odor, texture, and overall acceptability) analyses were performed at 0 and 6 months of freezing storage (-18°C). Results showed that by 5 kGy irradiation and freezing treatments, the counts of psychrotrophic and mesophilic bacteria reduced remarkably ( < 0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!