Correction to: Metrology for stable isotope reference materials: C/C and O/O isotope ratio value assignment of pure carbon dioxide gas samples on the Vienna PeeDee Belmnite-CO scale using dual-inlet mass spectrometry.

Anal Bioanal Chem

Surface and Trace Chemical Analysis Group, Materials Measurement Science Division, Materials Measurement Laboratory, National Institute of Standards and Technology, 100 Bureau Drive, Gaithersburg, MD, 20899, USA.

Published: May 2019

The authors would like to call the reader's attention to the fact that unfortunately the formula for the O17 correction parameter "a" is reported incorrectly as.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00216-019-01740-2DOI Listing

Publication Analysis

Top Keywords

correction metrology
4
metrology stable
4
stable isotope
4
isotope reference
4
reference materials
4
materials c/c
4
c/c o/o
4
o/o isotope
4
isotope ratio
4
ratio assignment
4

Similar Publications

Realizing quantum control and entanglement of particles is crucial for advancing both quantum technologies and fundamental science. Substantial developments in this domain have been achieved in a variety of systems. In this context, ultracold polar molecules offer new and unique opportunities because of their more complex internal structure associated with vibration and rotation, coupled with the existence of long-range interactions.

View Article and Find Full Text PDF

A Comparative Analysis of the Effects of Misaligning Different Trifocal Intraocular Lenses.

J Clin Med

December 2024

The David J Apple Center for Vision Research, Department of Ophthalmology, Heidelberg University Eye Clinic, University Hospital Heidelberg, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany.

This laboratory study aims to assess the effects of misaligning different trifocal intraocular lenses (IOLs) under varying spectral and corneal spherical aberration (SA) conditions. With an IOL metrology device under monochromatic and polychromatic conditions, the following models were studied: AT ELANA 841P, AT LISA Tri 839MP, FineVision HP POD F, Acrysof IQ PanOptix, and Tecnis Synergy ZFR00V. The SA was simulated using an aberration-free and average-SA cornea.

View Article and Find Full Text PDF

On Security Performance of SWIPT Multi-User Jamming Based on Mixed RF/FSO Systems with Untrusted Relay.

Sensors (Basel)

December 2024

Key Laboratory of Electromagnetic Wave Information Technology and Metrology of Zhejiang Province, College of Information Engineering, China Jiliang University, Hangzhou 310018, China.

This paper presents research on the security performance of a multi-user interference-based mixed RF/FSO system based on SWIPT untrusted relay. In this work, the RF and FSO channels experience Nakagami-m fading distribution and Málaga (M) turbulence, respectively. Multiple users transmit messages to the destination with the help of multiple cooperating relays, one of which may become an untrusted relay as an insider attacker.

View Article and Find Full Text PDF

This study contributes to improving the accuracy of temperature measurements with a platinum resistance temperature detector (RTD) by proposing techniques to mitigate the error due to self-heating by the operating current. An assessment of the measurement errors of the platinum RTD was carried out to study ways to improve their accuracy. High accuracy can be achieved by individual calibration using a voltage divider circuit to measure resistance, the substitution method, and the transitional measure.

View Article and Find Full Text PDF

Objectives: An analytical protocol based on isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS), which includes a peptide-based calibration strategy, was developed and validated for the determination of cardiac troponin I (cTnI) levels in clinical samples. Additionally, the developed method was compared with a protein-based calibration strategy, using cTnI serving as a model for low-abundant proteins. The aim is to evaluate new approaches for protein quantification in complex matrices, supporting the metrology community in implementing new methods and developing fit-for-purpose SI- traceable peptide or protein primary calibrators.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!