Transnasal endoscopic removal of displaced dental implants in the maxillary sinus can be done easily under local anesthesia. However, very little is known regarding the precaution of this technique. In this report, we present the case of a 63-year-old man who visited the otolaryngologic department with a displaced dental implant in the maxillary sinus. Transnasal endoscopic removal of the displaced dental implant was planned and performed. However, the displaced dental implant was lost during removal. The implant was not seen in the other parts of the nasal cavity nor in the other parts of the oral cavity. Finally, radiographs revealed the presence of the dental implant at the level of the esophagus, although the patient did not notice anything because of local anesthesia. Thus, we conclude that operators should take into account the possibility of aspiration or swallowing of an implant through the posterior nasal aperture during the removal procedure. Precautions should be taken to avoid the possibility of implant aspiration or implant ingestion.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1563/aaid-joi-D-18-00231 | DOI Listing |
J Prosthet Dent
January 2025
Assistant Professor, Restorative and Prosthodontic Department, The Ohio State University College of Dentistry, Columbus, OH.
Statement Of Problem: Although immediate implant loading has shown promising clinical results and high survival rates, an increased risk of implant failure and complications has been reported. Achieving consistently predictable outcomes with this approach remains a challenge, but evidence-based guidelines to assist in selecting suitable patients are lacking.
Purpose: The purpose of this retrospective clinical study was to investigate the success rate, survival rate, and complications of immediate implant loading compared with early and delayed loading.
J Prosthet Dent
January 2025
Assistant Professor, Department of Prosthodontic, College of Dental Medicine, Rangsit University, Phatum Thani, Thailand. Electronic address:
Statement Of Problem: Comprehensive data are needed on the performance of chemically activated, chairside hard reline materials when used with computer-aided design and computer-aided manufacturing (CAD-CAM) milled polymethyl methacrylate (PMMA) denture bases and conventionally processed bases. This lack of data affects decisions regarding the chairside reline material to be used for improving the fit and retention of relined complete dentures.
Purpose: The purpose of this in vitro study was to evaluate and compare the shear bond strength (SBS) of 3 chemically activated, chairside hard reline materials on CAD-CAM milled and conventional heat-polymerized PMMA denture bases.
J Forensic Odontostomatol
December 2024
Department of Advanced Biomedical Science-Legal Medicine Section, University of Naples "Federico II", Naples, Italy.
The great advances in diagnostic and therapeutic skills of most sectors of medicine and dentistry have led to an increasingly greater demand from patients for accuracy, attention and diligence by healthcare workers. Dentistry is one of the branches most frequently involved in claims for damages from malpractice, especially in those sectors that are particularly costly and of significant aesthetic value. Aim of the study was to compare data of malpractice claims with those of other Authors to identify similarities and/or differences in the results and to increase epidemiological knowledge in the area of dental malpractice.
View Article and Find Full Text PDFInt J Implant Dent
January 2025
Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi'an Jiaotong University, Xi'an, China.
Purpose: This study evaluated the accuracy of implant placement using a robotic system (Remebot) compared to freehand surgery and explored factors influencing accuracy.
Methods: This retrospective study included 95 implants placed in 65 patients, divided into robot-assisted (50 implants) and freehand (45 implants) groups. Platform, apical, and angular deviations were measured by superimposing preoperative plans and the postoperative CBCT images.
J Indian Prosthodont Soc
January 2025
Department of Prosthodontics, K M Shah Dental College and Hospital, Sumandeep Vidyapeeth, Vadodara, Gujarat, India.
Aim: The aim is to evaluate and compare stress distribution characteristics of ball, magnet, and positioned attachment systems in single and double implant-retained overdentures using the finite element method (FEM).
Setting And Design: In vitro (in silico study) finite element analysis (FEA).
Materials And Methods: A Styrofoam mandible with duplicated silicon mucosa was used to construct a mandibular complete denture.