Objective: To evaluate short-term effectiveness of revision total knee arthroplasty (TKA) with porous-coated metaphyseal Sleeve and MBT implant.
Methods: A clinical data of 23 patients (24 knees) who underwent revision TKA by using porous-coated metaphyseal Sleeve combined with MBT implant between March 2015 and April 2017 was retrospectively analyzed. There were 8 males (8 knees) and 15 females (16 knees). The age ranged from 48 to 85 years (mean, 65.4 years). The cause of revision TKA included infection in 14 knees, aseptic loosening in 8 knees, instability in 1 knee, and stiff knee in 1 knee. Bone defects were classified according to the Anderson Orthopaedic Research Institute (AORI) bone defect classification. The femoral defect was rated as type ⅡA in 5 knees, type ⅡB in 17 knees, and type Ⅲ in 2 knees; the tibial defect was rated as type ⅡA in 2 knees, type ⅡB in 20 knees, and type Ⅲ in 2 knees. The mean time between primary TKA and revision TKA was 30.6 months (range, 6-86 months). The preoperative range of motion (ROM) was (56.0±24.9)°. The preoperative Hospital for Special Surgery (HSS) total score was 41.9±14.2; and the pain and function scores were 8.5±5.2 and 33.4±13.5, respectively.
Results: All patients were followed up 12-39 months (mean, 25.6 months). The mean operation time was 2.2 hours (range, 1.6-2.9 hours). The mean intraoperative blood loss was 580 mL (range, 400-1 000 mL). There were 2 knees (8.3%) of intraoperative fracture associated with Sleeve insertion and 1 knee (4.2%) of acute postoperative infection at 25 days after revision TKA. All incisions healed by first intention. No deep venous thrombosis of lower extremity occurred. X-ray film showed that all implants were stable. At last follow-up, slight discomfort after exercise occurred in 4 knees (16.7%); end-of-stem pain in the tibia occurred in 1 knee (4.2%). The ROM was (114.6±5.1)°, which had significant improvement compared with the preoperative result ( =11.698, =0.000). The HSS total score (89.0±10.9), pain score (26.9±6.6), and function score (62.1±5.8) also had significant improvement compared with the preoperative results ( =15.616, =0.000; =12.522, =0.000; =10.076, =0.000).
Conclusion: The porous-coated metaphyseal Sleeve combined with MBT implant in revision TKA has a significant improvement in short-term effectiveness and no signs of implant loosening.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8337934 | PMC |
http://dx.doi.org/10.7507/1002-1892.201810026 | DOI Listing |
J Knee Surg
January 2025
Department of Orthopaedic Surgery, University of Louisville, Louisville, Kentucky.
Stiffness after total knee arthroplasty (TKA) can lead to decreased function and patient dissatisfaction. Manipulation under anesthesia (MUA) is often performed to improve range of motion (ROM); however, there is no consensus on indications or timing. The purpose of this study was to compare clinical results and patient-reported outcome measures (PROMs) between patients who underwent MUA versus those with an uncomplicated postoperative course following primary TKA.
View Article and Find Full Text PDFKnee
January 2025
IULS-University Institute for Locomotion and Sports, Pasteur 2 Hospital, University Côte d'Azur, Nice, France; ICARE Team, Côte d'Azur University, Inserm, CNRS, Valrose Institute of Biology, Nice, France. Electronic address:
Background: Several studies have demonstrated the interest in patient-specific custom cutting guides in total knee arthroplasty (TKA), but clinical improvement remains debated. The purpose of this study was to evaluate the functional outcomes (Forgotten Joint Score, FJS) of patients undergoing individualized TKA compared with those receiving off-the-shelf (OTS) implants, both using patient-specific cutting guides with personalized alignment over a minimum follow up period of 12 months. We hypothesized that individualized TKA demonstrates significantly better functional outcomes than OTS TKA (FJS and percentage of patients reaching the minimum clinically important difference).
View Article and Find Full Text PDFInt Orthop
January 2025
Department of Orthopaedic Surgery and Traumatology, Altmühltal Nature Park Clinics, Eichstätt, Germany.
Purpose: The outcome of elective total joint arthroplasty (TJA) in patients with Parkinson's disease (PD) is controversial due to the concomitant risk profile. This study investigated postoperative complications and revision rates following total hip (THA) and knee arthroplasty (TKA) in patients with PD.
Methods: Ninety-six patients with PD undergoing THA or TKA were matched 1:1 with non-PD patients using propensity score matching for age, sex and comorbidity (Charlson Comorbidity index, CCI).
Introduction: total knee arthroplasty (TKA) is a surgical procedure with a growing number of indications worldwide. The trend in recent years has been to reduce hospital stay without compromising safety and quality of care. The aim of this study was to determine whether early discharge (less than 24 hours) is associated with a higher rate of complications, readmissions and unscheduled visits in patients undergoing primary knee arthroplasty.
View Article and Find Full Text PDFBioengineering (Basel)
January 2025
Research & Development, Aesculap AG, 78532 Tuttlingen, Germany.
Instability remains one of the most common indications for revision after total knee arthroplasty. To gain a better understanding of how an implant will perform in vivo and support surgeons in selecting the most appropriate implant design for an individual patient, it is crucial to evaluate the implant constraint within clinically relevant ligament and boundary conditions. Therefore, this study investigated the constraint of three different implant designs (symmetrical implants with and without a post-cam mechanism and an asymmetrical medial-stabilized implant) under anterior-posterior shear forces and internal-external rotation moments at different flexion angles in human cadaveric knees using a six-degrees-of-freedom joint motion simulator.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!