A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Influences of aberration on spatial resolution of STED microscope in probing a specimenwith discontinuous refraction indices. | LitMetric

Probing depth and system aberrations have direct impacts on the spatial resolution of stimulated emission depletion (STED) microscopes. Based on the vectorial diffraction theory, the influence of coma and astigmatism on the focal patterns of STED microscopes in probing stratified mediums with discontinuous refractive indices (e.g., glass cover slip, solution, and biological samples, etc.) have been illustrated in detail. The spatial resolution of the STED system has been discussed by analyzing the full width at half-maximum size of the fluorescence spots. It is found that, while probing in stratified media with discontinuous refractive indices, the spatial resolution of a STED microscope can be very sensitive to the existence of aberrations, e.g., coma and astigmatism, at different probing depths, as a result of mismatched axial positions of the excitation and depletion patterns. The spatial resolution of STED can be degraded up to 1.87- and 1.95-fold compared to that without aberrations. Therefore, a careful evaluation of the influence of aberration and discontinuous refractive indices should be taken into account when applying a STED microscope to realize super-resolution images.

Download full-text PDF

Source
http://dx.doi.org/10.1364/AO.58.002112DOI Listing

Publication Analysis

Top Keywords

spatial resolution
20
resolution sted
16
sted microscope
12
discontinuous refractive
12
refractive indices
12
sted microscopes
8
coma astigmatism
8
probing stratified
8
sted
7
spatial
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!