Biomonitoring of bisphenols A, F, S in human milk and probabilistic risk assessment for breastfed infants.

Sci Total Environ

Foundation for the Promotion of Health and Biomedical Research in the Valencian Region, FISABIO-Public Health, 21, Avenida Catalunya, 46020 Valencia, Spain; Analytical Chemistry Department, University of Valencia, Edifici Jeroni Muñoz, Dr. Moliner 50, 46100 Burjassot, Spain; Public Health Laboratory of Valencia, 21, Avenida Catalunya, 46020 Valencia, Spain. Electronic address:

Published: June 2019

The present study addresses the presence of bisphenols A (BPA) and its analogs bisphenol F (BPF) and S (BPS) in milk of 120 mothers living in Valencia (Spain) and participating in the BETTERMILK project (year 2015). We also studied the factors that could influence the BPA levels and estimated the exposure and the risk for breast fed infants. The frequency of detection of total (conjugated + unconjugated) and unconjugated-BPA were 83% and 77%, with a geometric mean of 0.29 ng/mL and 0.15 ng/mL, respectively. The frequency of detection was much lower for total-BPF (22%) and total-BPS (1.1%). The place of residence of the mother and the use of personal care products showed significant association with BPA concentrations. The estimated daily intake of total-BPA for breastfed infants amounted to a geometric mean of 0.04 μg/kg bw and a 95th percentile of 1.0 μg/kg bw, below the tolerable daily intake of 4 μg/kg bw-day established by EFSA. To our knowledge, this is the largest biomonitoring study of bisphenols in human milk in Europe.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.scitotenv.2019.03.024DOI Listing

Publication Analysis

Top Keywords

bisphenols human
8
human milk
8
breastfed infants
8
frequency detection
8
daily intake
8
biomonitoring bisphenols
4
milk probabilistic
4
probabilistic risk
4
risk assessment
4
assessment breastfed
4

Similar Publications

Bisphenols may negatively impact human health. In this study, we propose the use of HPLC-FLD for the simultaneous determination of bisphenols in pericardial fluid samples collected from patients with coronary artery disease undergoing coronary artery bypass surgery. For sample preparation, a fast, simple, and "green" DLLME method was used, achieving mean recovery values in the range of 62%-98% with relative standard deviations between 2% and 6% for all analytes.

View Article and Find Full Text PDF

As a replacement of bisphenol A, bisphenol S (BPS) is commonly used in the wrappers and food containers of daily life. Epidemiological studies demonstrate a close link between BPS exposure and vascular diseases, where the biological activities of BPS remain scarcely known. Herein, the effects of BPS on endothelial function as well as the underlying mechanism were investigated in human umbilical vein endothelial cells (HUVECs) and mouse arteries.

View Article and Find Full Text PDF

Safer chemical alternatives to bisphenol (BP) have been a major pursuit of modern green chemistry and toxicology. Using a chemical similarity-based approach, it is difficult to identify minor structural differences that contribute to the significant changes of toxicity. Here, we used omics and computational toxicology to identify chemical features associated with BP analogue-induced embryonic toxicity, offering valuable insights to inform the design of safer chemical alternatives.

View Article and Find Full Text PDF

Covalent Organic Framework Nanofilm-Assisted Laser Desorption Ionization Mass Spectrometry for Rapid Screening of Parabens in Personal Care Products.

Rapid Commun Mass Spectrom

April 2025

State Key Laboratory of Environmental and Biological Analysis, Department of Chemistry, Hong Kong Baptist University, Hong Kong SAR, China.

Rational: People are widely exposed to parabens in their daily life, but parabens are endocrine disrupting chemicals that pose a threat to human health. Therefore, establishing a rapid screening method to enhance monitoring of parabens is necessary. Herein, a covalent organic framework (COF) nanofilm-assisted laser desorption ionization mass spectrometry (LDI-MS) method was established to screen parabens in personal care products (PCPs).

View Article and Find Full Text PDF

4D-printed programmable sample-/eluent-actuated solid-phase extraction device for trace metal analysis.

Anal Chim Acta

January 2025

Department of Chemistry, National Chung Hsing University, Taichung City, 402202, Taiwan, ROC. Electronic address:

Background: To integrate valves, manifolds, and solid-phase extraction (SPE) columns into a compact device is technically difficult. Four-dimensional printing (4DP) technologies, employing stimuli-responsive materials in three-dimensional printing (3DP), are revolutionizing the fabrication, functionality, and applicability of stimuli-responsive analytical devices that can show time-dependent shape programming to enable more complex geometric designs and functions. However, 4D-printed stimuli-responsive actuators and valves utilized to control flowing streams in SPE applications remain rare.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!