Objective: To determine the relationship between intraoperative flash visual evoked potential (FVEP) monitoring and visual function.

Methods: Intraoperative FVEPs were recorded from electrodes placed in the scalp overlying the visual cortex (Oz) after flashing red light stimulation delivered by Cadwell LED stimulating goggles in 89 patients. Restrictive filtering (typically 10-100 Hz), optimal reject window settings, mastoid reference site, total intravenous anesthetic (TIVA), and stable retinal stimulation (ensured by concomitant electroretinogram [ERG] recording) were used to enhance FVEP reproducibility.

Results: The relationship between FVEP amplitude change and visual outcome was determined from 179 eyes. One eye had a permanent intraoperative FVEP loss despite stable ERG, and this eye had new, severe postoperative visual dysfunction. Seven eyes had transient significant FVEP change (>50% amplitude decrease that recovered by the end of surgery), but only one of those had a decrease in postoperative visual acuity. FVEP changes in all eight eyes (one permanent FVEP loss plus seven transient FVEP changes) were related to surgical manipulation. In each case the surgeon was promptly informed of the FVEP deterioration and took remedial action. The other eyes did not have FVEP changes, and none of those eyes had new postoperative visual deficits.

Conclusions: Our FVEP findings relate to visual outcome with a sensitivity and specificity of 1.0. New methods for rapidly acquiring reproducible FVEP waveforms allowed for timely reporting of significant FVEP change resulting in prompt surgical action. This may have accounted for the low postoperative visual deficit rate (1%) in this series.

Download full-text PDF

Source
http://dx.doi.org/10.1017/cjn.2019.4DOI Listing

Publication Analysis

Top Keywords

postoperative visual
16
fvep
13
visual outcome
12
fvep changes
12
visual
11
intraoperative flash
8
flash visual
8
visual evoked
8
evoked potential
8
fvep loss
8

Similar Publications

Purpose: This study aims to examine the risk factors for catheter-associated urinary tract infection (CAUTI) following radical hysterectomy for cervical cancer (CC). Furthermore, the study seeks to develop a visual model that can effectively assist physicians in improving their proficiency in diagnosing, treating, and preventing CAUTIs.

Patients And Methods: 48 subjects who developed CAUTI postoperatively were assigned to the infection group.

View Article and Find Full Text PDF

Background: Tendon repairs often result in adhesion formation which can cause persisting functional deficits. Close proximity of healing tissues increases friction during tendon excursion, often leading to tendon tethering postoperatively. Despite continued improvements in techniques for tendon repairs, there is currently no consensus on the most effective modality to reduce adhesion formation.

View Article and Find Full Text PDF

Purpose: To evaluate the outcomes of scleral-fixated intraocular lenses (IOLs) implanted using either Yamane technique or Gore-Tex suture fixation, in comparison to intracapsular lens fixation, and to assess the efficacy of various lens formulas in achieving predicted refractive targets.

Patients And Methods: This study included 45 eyes from 44 patients with scleral-fixated IOLs, comprising 37 Yamane eyes and 8 Gore-Tex eyes. Preoperative refractive predictions from various formulae were compared with final postoperative refraction.

View Article and Find Full Text PDF

The mechanism and severity of mitral valve (MV) regurgitation (MR) play a critical role in guiding treatment decisions. Transthoracic echocardiography (TTE) is the primary diagnostic modality for evaluating MV disease. Discordant findings on TTE can be further quantified through transesophageal echocardiography (TEE).

View Article and Find Full Text PDF

We report a case of spontaneous total iris avulsion that occurred during corneal wound hydration following an uneventful phacoemulsification procedure. An 86-year-old woman underwent cataract surgery on her right eye, during which a single-piece acrylic intraocular lens (Bausch and Lomb Akreos Adapt Advanced Optics, Bausch and Lomb Incorporated, Rochester, NY, USA) was implanted in the bag, and the viscoelastic material was removed. During corneal wound hydration, total iris avulsion was observed, with the iris prolapsing out of the anterior chamber through the main wound.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!