Purpose: Over-filtration and subsequent hypotony are recognised complications of penetrating glaucoma procedures, especially when augmented with antimetabolites. Patients with uveitis are especially at risk of hypotony and this can reduce the final acuity achieved, compromise surgical outcomes and adversely affect the inflammatory status. The incidence of hypotony following XEN45 implant insertion is higher for uveitic patients and we present a method of surgically addressing this hypotony with transconjunctival compression sutures that are placed over the overdraining XEN45 implant.

Methods: We present a retrospective case series of consecutive uveitic glaucoma patients who had conjunctival compression sutures between 2015 and 2018 following XEN45 insertion, at the Manchester Royal Eye Hospital, UK. Two 9/0 nylon sutures were placed in a horizontal figure-of-eight conformation transconjunctivally across the overdraining bleb: one directly over the XEN45 implant and one at the posterior limit of the implant in order to restrict flow.

Results: Three patients underwent conjunctival compression sutures following XEN45 implant-related hypotony and all three had successful resolution of their hypotony and visual symptoms. No patients required long-term topical agents to control their intraocular pressure.

Conclusion: Conjunctival compression sutures are an effective option for addressing persistent hypotony following XEN45 implant insertion in patients with uveitic glaucoma.

Download full-text PDF

Source
http://dx.doi.org/10.1177/1120672119836339DOI Listing

Publication Analysis

Top Keywords

xen45 implant
16
compression sutures
16
uveitic glaucoma
12
conjunctival compression
12
hypotony
8
hypotony xen45
8
implant insertion
8
xen45
7
patients
6
compression
5

Similar Publications

Aim: To evaluate the short-term efficacy of XEN45 Gel Stent (XEN) implantation for primary open angle glaucoma (POAG) and pseudoexfoliation (PEX) glaucoma across two university eye clinics, aiming to assess the impact of varying center-specific protocols during the first postoperative year.

Methods: We retrospectively examined 282 patients (183 in center 1, 99 in center 2), who underwent XEN microstent implantation for uncontrolled POAG or PEX glaucoma. Parameters including intraocular pressure (IOP), IOP-lowering medication count, best corrected visual acuity (BCVA), and postoperative complications were evaluated over 12mo.

View Article and Find Full Text PDF

Italian XEN-Glaucoma Treatment Registry (XEN-GTR): Effectiveness and Safety at 36 Months of XEN45 Implant.

J Clin Med

December 2024

Department of Surgical, Medical, Molecular Pathology and of Critical Care Medicine, University of Pisa, Via Savi 10, 56126 Pisa, Italy.

: We evaluated the 3-year effectiveness and safety of XEN45, combined or not with phacoemulsification, in patients from the Italian XEN-Glaucoma Treatment Registry. : Data from glaucoma patients who underwent XEN45 alone or combined with phacoemulsification were analyzed. Changes in intraocular pressure (IOP) and the number of ocular hypotensive medications (OHMs) were tested with repeated measures ANOVA in last observation carried forward (LOCF) and per-protocol (PP) analyses.

View Article and Find Full Text PDF

Purpose: To investigate the long-term outcomes of XEN-45 implantation for glaucoma secondary to Fuchs uveitis syndrome (FUS), juvenile idiopathic arthritis (JIA)-related anterior uveitis and intermediate uveitis (IU).

Methods: This retrospective study evaluated 19 eyes with FUS, 10 eyes with JIA, and nine eyes with IU that underwent XEN-45 Gel Stent implantation. The primary outcome measure was 3-year surgical success, defined as a ≥20% reduction in intraocular pressure (IOP), with a target IOP of 6-21 mmHg.

View Article and Find Full Text PDF

No consensus has been reached on the adequate dose of mitomycin C (MMC) in XEN45 gel stent implantation. Lower doses have the potential to reduce MMC-linked side effects. This study aimed to evaluate treatment efficacy of ab interno XEN45 gel stent in primary open-angle glaucoma (POAG) with three different MMC doses.

View Article and Find Full Text PDF

Purpose XEN45 Gel Stent and glaucoma drainage device (GDD) implantation is safe and effective for glaucoma treatment and should be taught during glaucoma fellowship training. However, complications may still occur, with potentially sight-threatening consequences. The purpose of this study is to describe the management of complications following a series of XEN45 Gel Stent and GDD surgeries performed over the course of glaucoma fellowship training.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!