A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Developing a personalized closed-loop controller of medically-induced coma in a rodent model. | LitMetric

Developing a personalized closed-loop controller of medically-induced coma in a rodent model.

J Neural Eng

Department of Electrical and Computer Engineering, Viterbi School of Engineering, University of Southern California, Los Angeles, CA 90089, United States of America.

Published: June 2019

Objective: Personalized automatic control of medically-induced coma, a critical multi-day therapy in the intensive care unit, could greatly benefit clinical care and further provide a novel scientific tool for investigating how the brain response to anesthetic infusion rate changes during therapy. Personalized control would require real-time tracking of inter- and intra-subject variabilities in the brain response to anesthetic infusion rate while simultaneously delivering the therapy, which has not been achieved. Current control systems for medically-induced coma require a separate offline model fitting experiment to deal with inter-subject variabilities, which would lead to therapy interruption. Removing the need for these offline interruptions could help facilitate clinical feasbility. In addition, current systems do not track intra-subject variabilities. Tracking intra-subject variabilities is essential for studying whether or how the brain response to anesthetic infusion rate changes during therapy. Further, such tracking could enhance control precison and thus help facilitate clinical feasibility.

Approach: Here we develop a personalized closed-loop anesthetic delivery (CLAD) system in a rodent model that tracks both inter- and intra-subject variabilities in real time while simultaneously controlling the anesthetic in closed loop. We tested the CLAD in rats by administrating propofol to control the electroencephalogram (EEG) burst suppression. We first examined whether the CLAD can remove the need for offline model fitting interruption. We then used the CLAD as a tool to study whether and how the brain response to anesthetic infusion rate changes as a function of changes in the depth of medically-induced coma. Finally, we studied whether the CLAD can enhance control compared with prior systems by tracking intra-subject variabilities.

Main Results: The CLAD precisely controlled the EEG burst suppression in each rat without performing offline model fitting experiments. Further, using the CLAD, we discovered that the brain response to anesthetic infusion rate varied during control, and that these variations correlated with the depth of medically-induced coma in a consistent manner across individual rats. Finally, tracking these variations reduced control bias and error by more than 70% compared with prior systems.

Significance: This personalized CLAD provides a new tool to study the dynamics of brain response to anesthetic infusion rate and has significant implications for enabling clinically-feasible automatic control of medically-induced coma.

Download full-text PDF

Source
http://dx.doi.org/10.1088/1741-2552/ab0ea4DOI Listing

Publication Analysis

Top Keywords

medically-induced coma
24
brain response
24
response anesthetic
24
anesthetic infusion
24
infusion rate
24
intra-subject variabilities
16
rate changes
12
offline model
12
model fitting
12
control
9