Despite the availability of a large number of antibody and DNA based methods for detection and quantification of allergens in food there remain significant difficulties in selecting the optimum technique to employ. Published methods from research groups mostly contain sufficient detail concerning target antigen, calibration procedures and method performance to allow replication by others. However, routine allergen testing by the food industry relies upon commercialised test kits and frequently the suppliers provide disappointingly little specification detail on the grounds that this is proprietary information. In this review we have made a critical assessment of the published literature describing the performance of both commercial and non-commercial test kits for food allergens over the period 2008-2018. Mass spectrometric methods, which have the potential to become reference methods for allergens, are not covered in this review. Available information on the specifications of commercial ELISA and LFD test kits are tabulated for milk, egg and peanut allergens, where possible linking to publications concerning collaborative studies and proficiency testing. For a number of commercial PCR test kits, specifications provided by manufacturers for detection of a small selection of allergen are tabulated. In conclusion we support the views of others of the critical need for allergen reference materials as the way forward to improve the comparability of different testing strategies in foods.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1080/19440049.2019.1579927 | DOI Listing |
J Biophotonics
January 2025
Faculty of Medicine, Department of Biophysics, Yuksek Ihtisas University, Ankara, Türkiye.
Zerumbone is a sesquiterpene phytochemical with cytotoxic activity against cancer. This study aimed to evaluate the effect of zerumbone on cell viability by WST-1 test, apoptosis by TUNEL, lipid peroxidation markers (malondialdehyde, MDA, and 4-hydroxynonenal, HNE) by using assay kits, and biomolecular changes by ATR-FTIR spectroscopy in A549 cells. After zerumbone (0-100 μM) incubation for 24, 48, and 72 h, the number of TUNEL-positive cells was found to be higher in zerumbone-treated cells than in controls, in consistent with cell morphology results.
View Article and Find Full Text PDFNanoscale
January 2025
Division of Biophotonics and Imaging, Biomedical Technology Wing, Sree Chitra Tirunal Institute for Medical Sciences and Technology, Poojappura, Thiruvananthapuram-695012, Kerala, India.
The widespread adoption and commercialization of lateral flow assays (LFAs) for clinical diagnosis have been hindered by limitations in sensitivity, specificity, and the absence of quantitative data. To address these challenges, we developed aptamer-architectured gold nanoparticles as nanozymes that catalytically convert -phenylenediamine (PPD) into Bandrowski's base (BB), thereby amplifying signal strength and sensitivity. The physiochemical properties of the nanozymes were characterized and their specific binding efficiency was demonstrated using experimental studies.
View Article and Find Full Text PDFHum Exp Toxicol
January 2025
Department of Gynecology and Obstetrics, Fuyong People's Hospital, Shenzhen, China.
Gestational diabetes mellitus (GDM) is a metabolic disorder that arises during pregnancy and heightens the risk of placental dysplasia. Ginsenoside Re (Re) may stabilize insulin and glucagon to regulate glucose levels, which may improve diabetes-associated diseases. This study aims to investigate the mechanism of Re in high glucose (HG)-induced apoptosis of trophoblasts through endoplasmic reticulum stress (ERS)-related protein CHOP/GADD153.
View Article and Find Full Text PDFCancers (Basel)
December 2024
Centro de Investigación Biomédica en Red de Epidemiología y Salud Pública (CIBERESP), 28029 Madrid, Spain.
: Implementing self-sampling (SS) in cervical cancer screening requires comparable results to clinician-collected samples (CCS). Agreement measures are essential for evaluating HPV test performance. Previous studies on non-paired samples have reported higher viral cycle threshold (Ct) values in SS compared to CCS, affecting sensitivity for detecting cervical intraepithelial neoplasia grade 2 or worse (CIN2+).
View Article and Find Full Text PDFJ Cancer Prev
December 2024
Department of Internal Medicine, Seoul National University Bundang Hospital, Seongnam, Korea.
Serological tests for needs local validation as the diagnostic accuracy may vary depending on the prevalence of . . This study examined the diagnostic performance of two ELISA, GastroPanel (GastroPanel ELISA; Biohit Oyj) and GENEDIA (GENEDIA .
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!