Digital holographic microscopy enables the 3D reconstruction of volumetric samples from a single-snapshot hologram. However, unlike a conventional bright-field microscopy image, the quality of holographic reconstructions is compromised by interference fringes as a result of twin images and out-of-plane objects. Here, we demonstrate that cross-modality deep learning using a generative adversarial network (GAN) can endow holographic images of a sample volume with bright-field microscopy contrast, combining the volumetric imaging capability of holography with the speckle- and artifact-free image contrast of incoherent bright-field microscopy. We illustrate the performance of this "bright-field holography" method through the snapshot imaging of bioaerosols distributed in 3D, matching the artifact-free image contrast and axial sectioning performance of a high-NA bright-field microscope. This data-driven deep-learning-based imaging method bridges the contrast gap between coherent and incoherent imaging, and enables the snapshot 3D imaging of objects with bright-field contrast from a single hologram, benefiting from the wave-propagation framework of holography.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6401162PMC
http://dx.doi.org/10.1038/s41377-019-0139-9DOI Listing

Publication Analysis

Top Keywords

snapshot imaging
12
bright-field microscopy
12
cross-modality deep
8
deep learning
8
enables snapshot
8
bright-field contrast
8
contrast single
8
single hologram
8
artifact-free image
8
image contrast
8

Similar Publications

Real-Time Quantification of Gas Leaks Using a Snapshot Infrared Spectral Imager.

Sensors (Basel)

January 2025

Department of Optical Engineering, Utsunomiya University, 7-2-1 Yoto, Utsunomiya 321-8585, Japan.

We describe the various steps of a gas imaging algorithm developed for detecting, identifying, and quantifying gas leaks using data from a snapshot infrared spectral imager. The spectral video stream delivered by the hardware allows the system to combine spatial, spectral, and temporal correlations into the gas detection algorithm, which significantly improves its measurement sensitivity in comparison to non-spectral video, and also in comparison to scanning spectral imaging. After describing the special calibration needs of the hardware, we show how to regularize the gas detection/identification for optimal performance, provide example SNR spectral images, and discuss the effects of humidity and absorption nonlinearity on detection and quantification.

View Article and Find Full Text PDF

Objective and continuous monitoring of Parkinson's disease (PD) tremor in free-living conditions could benefit both individual patient care and clinical trials, by overcoming the snapshot nature of clinical assessments. To enable robust detection of tremor in the context of limited amounts of labeled training data, we propose to use prototypical networks, which can embed domain expertise about the heterogeneous tremor and non-tremor sub-classes. We evaluated our approach using data from the Parkinson@Home Validation study, including 8 PD patients with tremor, 16 PD patients without tremor, and 24 age-matched controls.

View Article and Find Full Text PDF

Something Old and Something New-A Pilot Study of Shrinkage and Modern Imaging Devices.

Life (Basel)

December 2024

Department of Plastic and Hand Surgery and Laboratory for Tissue Engineering and Regenerative Medicine, University Hospital Erlangen, Friedrich-Alexander University Erlangen-Nürnberg (FAU), 91054 Erlangen, Germany.

Shrinkage, a heat-induced process, reorganizes collagen fibers, thereby reducing wound surface area. This technique, commonly applied in surgeries like periareolar mastopexy and skin grafting, is well-established. Despite its widespread use, modern imaging has recently enabled detailed observation of shrinkage's effects on tissue temperature and oxygenation.

View Article and Find Full Text PDF

Historically, electrophysiological correlates of scene processing have been studied with experiments using static stimuli presented for discrete timescales where participants maintain a fixed eye position. Gaps remain in generalizing these findings to real-world conditions where eye movements are made to select new visual information and where the environment remains stable but changes with our position and orientation in space, driving dynamic visual stimulation. Co-recording of eye movements and electroencephalography (EEG) is an approach to leverage fixations as time-locking events in the EEG recording under free-viewing conditions to create fixation-related potentials (FRPs), providing a neural snapshot in which to study visual processing under naturalistic conditions.

View Article and Find Full Text PDF

This study shows an implementation of neutron-gamma pulse shape discrimination (PSD) using a two-dimensional convolutional neural network. The inputs to the network are snapshots of the unprocessed, digitized signals from a BC501A detector. By exposing a BC501A detector to a Cf-252 source, neutron and gamma signals were collected to create a training dataset.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!