Purpose: To compare the accuracy of preoperative biometry-based formulas to intraoperative aberrometry (IA) with respect to predicting refractive outcomes after cataract surgery in short eyes.

Setting: Private practice and community-based ambulatory surgery center.

Design: Retrospective consecutive case series.

Methods: Eyes with an axial length (AL) shorter than 22.1 mm underwent cataract extraction and intraocular lens (IOL) implantation. The predicted residual refractive error was calculated preoperatively using Hoffer Q, Holladay 2, Haigis, Barrett Universal II, and Hill-RBF formulas and intraoperatively using IA. The postoperative spherical equivalent (SE) was compared with the predicted SE to evaluate the accuracy of each aforementioned method.

Results: Fifty-one eyes from 38 patients met criteria to be included in the analysis. Without optimizing the formulas specifically for short eyes, the mean numerical errors (MNEs) associated with Hoffer Q, Holladay 2, Haigis, Barrett Universal II, Hill-RBF, and IA were -0.08 (95% confidence interval [CI], -0.30 to 0.13), -0.14 (95% CI, -0.35 to 0.07), +0.26 (95% CI, 0.05 to 0.47), +0.11 (95% CI, -0.10 to 0.32), +0.07 (95% CI, -0.14 to 0.28), and +0.00 (95% CI, -0.21 to 0.21), respectively (P < .001). The proportion of eyes within ±0.5 diopter (D) of the predicted SE were 49.0%, 43.1%, 52.9%, 52.9%, 60.8%, and 58.8%, respectively (P = .06). The prediction outcomes from IA were statistically better than Haigis, but not other formulas. When formula and IA predictions differed by 0.5 D or more, IA's ability to recommend a more emmetropic outcome was no better than chance (50%).

Conclusions: Intraoperative aberrometry is not significantly different from the best preoperative biometry-based methods available for IOL power selection in short eyes.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jcrs.2018.12.016DOI Listing

Publication Analysis

Top Keywords

intraoperative aberrometry
8
intraocular lens
8
short eyes
8
hoffer holladay
8
holladay haigis
8
haigis barrett
8
barrett universal
8
universal hill-rbf
8
95%
6
aberrometry versus
4

Similar Publications

Background/aim: This study aimed to evaluate astigmatism after cataract surgery by comparing the use of an intraoperative aberrometer combined with an image-guided system (VLynk) an image-guided system alone (Verion) in patients with significant lens opacity.

Patients And Methods: The main outcomes included the corrected distance visual acuity (CDVA), astigmatism, spherical equivalent (SE) status, and the predicting factors for reduced astigmatism in the two groups.

Results: In this study, 73 patients were enrolled in the study group (VLynk); 76 individuals constituted the control group (Verion).

View Article and Find Full Text PDF

Commentary- Intraoperative aberrometry-assisted refractive optimization of SFIOL.

Indian J Ophthalmol

January 2025

Cornea, Cataract and Refractive Surgery Services, Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India.

View Article and Find Full Text PDF

Scleral-fixated intraocular lens (SFIOL) is a widely used technique for IOL implantation in patients where capsular support is insufficient. Most surgeons have shifted away from sutured to sutureless SFIOL techniques where haptics of a multifocal IOL are inserted in scleral tunnels/flaps. Large-scale publications have shown wide variation in the refractive status of eyes post-SFIOL even in the best of the hands.

View Article and Find Full Text PDF

Purpose: To compare the refractive prediction accuracy of the Optiwave Refractive Analysis (ORA) SYSTEM with the Barrett True-K (BTK) formula in calculating intraocular lens (IOL) power in eyes that underwent cataract surgery after previous myopic photorefractive keratectomy (PRK) or laser-assisted in situ keratomileusis (LASIK).

Methods: This retrospective study evaluated patients aged ≥22 years with prior myopic PRK or LASIK who underwent unilateral or bilateral cataract removal and monofocal IOL implantation using the ORA SYSTEM at 177 sites in the United States. Two datasets were analyzed: All Eyes (ie, all eligible eyes) and First Surgery Eyes (ie, each patient's first implanted eye).

View Article and Find Full Text PDF

Purpose: To assess ocular higher-order aberrations (HOAs) following ray trace guided laser in situ keratomileusis (LASIK).

Methods: Retrospective review at a single-site ophthalmology practice. Two hundred and fifty eyes of 250 patients with myopia and astigmatism undergoing ray trace LASIK were randomly reviewed (Wavelight Plus, Alcon).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!