Purpose: Computerized insulin dosing tools (CIDT) have been shown to improve the care of critically ill patients with hyperglycemia. Application of a CIDT in addition to a diabetic ketoacidosis (DKA) order set for the treatment of DKA has not been evaluated. Our goal was to determine the effects the CIDT would have on the treatment of a patient with DKA.

Methods: In this retrospective, pre-post chart review, a provider-driven insulin dosing strategy (pregroup) was compared to the CIDT (postgroup) with 24-hour pharmacist monitoring. The CIDT utilized an equation that incorporated a patient's most recent blood glucose (BG) value and recommended a rate of insulin (units/hour) every hour.

Results: All baseline characterizes were similar between the 2 groups. There were no significant differences in average time to anion gap closure (≤ 12 mEq/L) or intensive care unit length of stay between the pregroup and postgroup (12.5 [6] hours vs 10.5 [7] hours, = 0.235; 40.6 [24] hours vs 40.8 [24] hours, = 0.945). Although not statistically significant, 17 hypoglycemic events (BG < 70 mg/dL) occurred in the pregroup with 4 being severe (BG < 50 mg/dL) while 5 hypoglycemic events occurred in the postgroup, none of which were severe.

Conclusion: This study suggests, when compared to a provider-driven insulin dosing strategy, the CIDT with 24-hour pharmacist monitoring is efficacious and safe for treatment of patients with a primary diagnosis of DKA.

Download full-text PDF

Source
http://dx.doi.org/10.1177/0897190019834367DOI Listing

Publication Analysis

Top Keywords

insulin dosing
16
computerized insulin
8
diabetic ketoacidosis
8
provider-driven insulin
8
dosing strategy
8
24-hour pharmacist
8
pharmacist monitoring
8
[24] hours
8
hypoglycemic events
8
cidt
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!