Corneal ectasia associated with postoperative hypotony.

Can J Ophthalmol

Illinois Eye and Ear Infirmary, Department of Ophthalmology and Visual Sciences, University of Illinois, Chicago, Ill. Electronic address:

Published: February 2019

Importance: Although post-operative hypotony is common, many ophthalmologists argue that ocular hypotony is relatively inconsequential and question its occurrence as a surgical complication. Corneal changes related to ocular hypotony has seldom been described.

Objective: To describe corneal topographical changes and ectasia occur in patients who experienced hypotony after glaucoma filtering procedures.

Design: Prospective case series on adults who presented to the University of Illinois glaucoma service from October 2016 to September 2017 who had undergone glaucoma drainage surgeries with at least 3 months of ocular hypotony.

Setting: Single, referral center.

Participants: Adults who had undergone glaucoma drainage surgeries with at least two separate post-operative intraocular pressure readings of 5 mmHg or less measured by Goldmann applanation tonometry in one or both eyes were included. Patient with less than 3 months of persistent hypotony and/or had undergone previous corneal surgeries, had a history of corneal ectasia prior to glaucoma filtering surgeries, or had a history of uveitis were excluded.

Intervention/exposures: Slit lamp photography, corneal topography, and anterior segment optical coherence tomography were obtained from all patients at the time of enrollment.

Main Outcomes: The development of irregular astigmatism on topography, corneal ectasia on OCT and changes in best-corrected spectacle visual acuity.

Results: A total of nine eyes of seven patients were included. Significant associations between age, thin central corneal thickness and the development of irregular corneal astigmatism were found (p<0.05). Irregular corneal astigmatism was associated with a decreased best-corrected spectacle visual acuity (p=0.02). We also report a case of bilateral corneal ectasia associated with corneal sutures in the setting of hypotony.

Conclusions And Relevance: We illustrate the development of decreased visual acuity associated with irregular corneal astigmatism and the potential for the development of irreversible corneal thinning as complications of persistent hypotony post glaucoma filtering surgeries.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7048191PMC
http://dx.doi.org/10.1016/j.jcjo.2018.03.014DOI Listing

Publication Analysis

Top Keywords

corneal ectasia
12
corneal
9
ocular hypotony
8
glaucoma filtering
8
undergone glaucoma
8
glaucoma drainage
8
drainage surgeries
8
surgeries history
8
development irregular
8
hypotony
6

Similar Publications

To report a novel application within the USA of excimer ablation for the normalization of central corneal refractive irregularity, combined with higher fluence CXL in the effective management and visual rehabilitation of progressive keratoconus. 17 consecutive cases with progressive keratoconus were treated with corneal surface excimer laser ablation normalization using topography-guided (Contura) myopic ablation for customized corneal re-shaping with a 6 mm optical zone. The epithelial removal was accounted for by adding a -2.

View Article and Find Full Text PDF

Corneal cross-linking.

Prog Retin Eye Res

December 2024

ELZA Institute, Webereistrasse 2, CH-8953, Dietikon, Switzerland; Laboratory for Ocular Cell Biology, University of Zurich, Winterthurerstrasse 190, CH-8057, Zurich, Switzerland; Faculty of Medicine, University of Geneva, Rue Michel-Servet 1, CH-1206, Geneva, Switzerland. Electronic address:

First introduced over 20 years ago as a treatment for progressive keratoconus, the original "Dresden" corneal cross-linking (CXL) protocol involved riboflavin saturation of the stroma, followed by 30 min of 3 mW/cm-intensity ultraviolet-A (UV-A) irradiation. This procedure generates reactive oxygen species (ROS) that cross-link stromal molecules, thereby stiffening the cornea and counteracting the ectasia-induced weakening. Due to their large size, riboflavin molecules cannot readily pass through the corneal epithelial cell tight junctions; thus, epithelial debridement was performed.

View Article and Find Full Text PDF

Purpose: Eye rubbing is considered to play a significant role in the progression of keratoconus and of corneal ectasia following refractive surgery. To our knowledge, no tool performs an objective quantitative evaluation of eye rubbing using a device that is familiar to typical patients. We introduce here an innovative solution for objectively quantifying and preventing eye rubbing.

View Article and Find Full Text PDF

Visual Improvement With Wavefront-Guided Scleral Lenses for Irregular Corneal Astigmatism.

Eye Contact Lens

December 2024

Cornea and Laser Eye Institute-CLEI Center for Keratoconus (J.D.G., B.S., T.P., C.E., P.S.H., S.A.G.), Teaneck, NJ; Department of Ophthalmology (J.D.G., D.K., P.S.H., S.A.G.), Rutgers-New Jersey Medical School, Newark, NJ; TX; OVITZ Corporation (N.B., J.W.), Rochester, NY; College of Optometry (G.Y.), University of Houston, Houston, TX.

Purpose: To report interim results of a single center, randomized, double-blind, crossover-controlled clinical trial comparing wavefront-guided (wfg) scleral lenses (SLs) to traditional scleral lenses (tSLs) for patients with a history of irregular corneal astigmatism (ICA).

Methods: Thirty-one ICA eyes of 18 participants were reviewed, 23 with keratoconus, six postcorneal refractive ectasia, and two postpenetrating keratoplasty. Patients with corneal or lens opacities were not excluded from participating.

View Article and Find Full Text PDF

Purpose: To compare the parameters and indices of a novel swept-source optical coherence tomography device (SS-OCT, ANTERION) with those of a rotating Scheimpflug camera (RSC)-based tomograph (Pentacam) in normal and keratoconic (KC) eyes.

Methods: This prospective, monocentric, cross-sectional study included individuals with unoperated normal and KC eyes, selecting one eye per subject. Ectasia-specific parameters analysed with the SS-OCT were difference in mean keratometry (K) in the inferior and superior meridians, maximum keratometry value (K), elevation of the posterior surface at the thinnest point, screening corneal objective risk of ectasia (SCORE) and thinnest point thickness.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!