A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Risperdal CONSTA Needle Detachment. Incidence Rates Before and After Kit Redesign: A Retrospective Study using Electronic Health Records and Natural Language Processing in the Department of Veterans Affairs. | LitMetric

Introduction: Janssen received reports of needle detachments for Risperdal CONSTA and, in response, redesigned the kit.

Objective: The study objective was to estimate the rate of Risperdal CONSTA needle detachments prior to and after the introduction of a redesigned kit.

Methods: This retrospective study used record abstraction in the US Department of Veterans Affairs (VA). The 3 phases included: (1) a pilot study for methods evaluation in a sample of 6 hospitals with previously reported detachments; (2) a baseline study to ascertain the baseline detachment rate; and (3) a follow-up study to ascertain the rate for the redesigned kit. Administrative codes and natural language processing with clinical review were used to identify detachments.

Results: Pilot: we identified a subset of spontaneously reported detachments and several previously unreported events. In the baseline study (original device), from January through December 2013, 22 needle detachments were identified among 47,934 administrations of the drug in a census of administrations in the VA; an incidence of 0.0459%. In the follow-up study (redesigned device), from December 2015 through December 2016, there were 14 reported detachments in 41,819 injections, 0.0335%. This represents a reduction of 27% from the baseline.

Conclusion: This approach enabled us to identify needle detachments we would not have otherwise found ("solicited"). However, it likely resulted in incomplete outcome ascertainment. While this may have resulted in lower overall rates, it did not bias the comparison of the baseline and follow-up studies. The results showed that the redesigned Risperdal CONSTA kit reduced the incidence of needle detachment events in the VA.

Funding: Janssen Pharmaceuticals, Inc.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6534640PMC
http://dx.doi.org/10.1007/s40120-019-0130-7DOI Listing

Publication Analysis

Top Keywords

risperdal consta
16
needle detachments
16
reported detachments
12
consta needle
8
needle detachment
8
study
8
retrospective study
8
natural language
8
language processing
8
department veterans
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!