Continuous flow peritoneal dialysis (CFPD) is performed using a continuous flux of dialysis fluid via double or dual-lumen PD catheters, allowing a higher dialysate flow rate (DFR) than conventional treatments. While small clinical studies have revealed greatly improved clearances using CFPD, the inability to predict ultrafiltration (UF) may confer a risk of potentially harmful overfill. Here we performed physiological studies of CFPD using the extended 3-pore model.A 9-h CFPD session was simulated for: slow (dialysate to plasma creatinine [D/P crea] < 0.6), fast (D/P crea > 0.8) and average (0.6 ≤ D/P crea ≤ 0.8) transporters using 1.36%, 2.27%, or 3.86% glucose solutions. To avoid overfill, we applied a practical equation, based on the principle of mass-balance, to predict the UF rate during CFPD treatment.Increasing DFR > 100 mL/min evoked substantial increments in small- and middle-molecule clearances, being 2 - 5 times higher compared with a 4-h continuous ambulatory PD (CAPD) exchange, with improvements typically being smaller for average and slow transporters. Improved UF rates, exceeding 10 mL/min, were achieved for all transport types. The β-microglobulin clearance was strongly dependent on the UF rate and increased between 60% and 130% as a function of DFR. Lastly, we tested novel regimes as an alternative strategy to prevent overfill, being effective for 1.36% and 2.27%, but not for 3.86% glucose.While we find substantial increments in solute and water clearance with CFPD, previous studies have shown similar improvements using high-volume tidal automated PD (APD). Lastly, the current results need confirmation by studies .
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3747/pdi.2018.00225 | DOI Listing |
Langmuir
January 2025
Faculty of Science, Yamagata University, 1-4-12, Kojirakawa, Yamagata 990-8560, Japan.
The aggregation and accumulation of amyloid β 42 (Aβ42) peptides on the surface of brain cells is associated with Alzheimer's disease (AD); however, the underlying molecular mechanisms remain unclear. Herein, we used a unique brain-mimetic open system that continuously flows Aβ42 solution to analyze the initial aggregation and adsorptive nature of Aβ42 at physiological concentrations on the lipid membrane. The open system accelerated the adsorption and dimerization kinetics.
View Article and Find Full Text PDFCardiol Rev
January 2025
From the Department of Neurological Surgery, Montefiore Medical Center, Albert Einstein College of Medicine, Bronx, NY.
Endosaccular flow disruption has emerged as a transformative approach for treating wide-neck intracranial aneurysms, which are characterized by neck diameters exceeding 4 millimeters or dome-to-neck ratios below 2. This review examines the technical specifications and clinical outcomes of major endosaccular devices, including the Woven EndoBridge (WEB) device, the Artisse embolization device, the Medina embolization device, the neck bridging device for bifurcation aneurysms, the polycarbonate urethane membrane-assisted device, the Galaxy saccular endovascular aneurysm lattice, and the Contour Neurovascular System. Analysis of pivotal trials reveals varying degrees of efficacy and safety across platforms.
View Article and Find Full Text PDFBackground: Regionally anticoagulated continuous renal replacement therapy with citrate is the first choice for critically ill patients with acute kidney injury. If citrate that reaches the patient exceeds the metabolic capacity, metabolic alkalosis will follow. Bicarbonate from the treatment fluids will also reach the patient and add to the bicarbonate load.
View Article and Find Full Text PDFPulmonology
December 2025
Sorbonne Université, INSERM, UMRS1158 Neurophysiologie Respiratoire Expérimentale et Clinique, Paris, France.
Background: Nasal high flow (NHF) has been proposed to sustain high intensity exercise in people with COPD, but we have a poor understanding of its physiological effects in this clinical setting.
Research Question: What is the effect of NHF during exercise on dynamic respiratory muscle function and activation, cardiorespiratory parameters, endurance capacity, dyspnoea and leg fatigue as compared to control intervention.
Study Design And Methods: Randomized single-blind crossover trial including COPD patients.
Pulmonology
December 2025
Department of Emergency and Intensive Care, Fondazione IRCCS San Gerardo dei tintori, Monza, Italy.
Background: Non-invasive helmet respiratory support is suitable for several clinical conditions. Continuous-flow helmet CPAP systems equipped with HEPA filters have become popular during the recent Coronavirus pandemic. However, HEPA filters generate an overpressure above the set PEEP.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!