Single-arc VMAT optimization for dual-layer MLC.

Phys Med Biol

Department of Radiation Oncology, University of California Los Angeles, Los Angeles, CA, United States of America.

Published: May 2019

Dual-layer multi-leaf collimator (DLMLC) has recently attracted renewed interest due to its good balance among resolution, low leakage, and high fabricability. However, existing progressive sampling based volumetric modulated arc therapy (VMAT) algorithm is ineffective for DLMLC, requiring more arcs to achieve dosimetry comparable to VMAT plans with higher resolution single-layer MLC (SLMLC). In this study, we develop a novel single-arc VMAT optimization framework to take advantage of the unique DLMLC characteristics fully. Direct aperture optimization (DAO) for single-arc DLMLC VMAT was formulated as a least square dose fidelity objective, along with an anisotropic total variation term to regulate the fluence smoothness and a single segment term for forming simple apertures. The DAO was solved through alternating optimization approach. The DLMLC deliverability constraint and the MLC leaf speed constraint were formulated as the optimization constraints and solved using a graph optimization algorithm. Feasibility of the proposed framework was tested on a brain, a lung, and a prostate cancer patient. The framework was further adapted for a simultaneous integrated boost (SIB) case. The single-arc DLMLC-10 mm (leaf width) plan was compared against single-arc SLMLC VMAT plans including SLMLC-5mm, SLMLC-10mm, and SLMLC with 10 mm leaf width and 5 mm leaf step size (SLMLC-10mm-5mm). Compared with the SLMLC-10mm plan and the SLMLC-10mm-5mm plan, with the same target coverage, the DLMLC-10 mm plan reduced R50 by 30.7% and 10.0%, the average max OAR dose by 5.79% and 3.7% of the prescription dose, and the average mean OAR dose by 4.18% and 2.1% of the prescription dose, respectively. The plan quality is comparable to that of the SLMLC-5mm plan. The novel single-arc VMAT optimization framework for DLMLC utilizes two MLC layers to improve the effective modulation resolution and afford more sophisticated modulation. Consequently, DLMLC VMAT achieves superior dosimetry to SLMLC VMAT with the same leaf width.

Download full-text PDF

Source
http://dx.doi.org/10.1088/1361-6560/ab0dddDOI Listing

Publication Analysis

Top Keywords

single-arc vmat
12
vmat optimization
12
leaf width
12
vmat
8
vmat plans
8
novel single-arc
8
optimization framework
8
dlmlc vmat
8
slmlc vmat
8
oar dose
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!