A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Field performance of the INSTI HIV-1/-2 antibody test in two South African antenatal clinics. | LitMetric

Field performance of the INSTI HIV-1/-2 antibody test in two South African antenatal clinics.

J Med Virol

Department of Internal Medicine, Division of Infectious Diseases, University of Pretoria, Tshwane, South Africa.

Published: July 2019

This was a prospective study that assessed field performance of the INSTI HIV-1/-2 antibody test (INSTI test) in two antenatal clinics in South Africa (SA). INSTI test was evaluated against rapid tests used at these clinics, and pooled nucleic acid amplification testing (NAAT) performed for individuals with negative rapid tests. Three hundred and eighty-six pregnant women were enrolled; 334 (86.5%) with negative results on the screening rapid test, and 52 (13.5%; 95% confidence interval [CI]: 10.2-17.3%) with positive results on screening and confirmatory rapid tests. INSTI test yielded the same results as other rapid tests in all participants, thus showing a 100% sensitivity (95% CI: 93.2-100.0%) and specificity (95% CI: 98.9-100.0%). Pooled NAAT was performed for 290 participants who had negative rapid tests, and yielded negative results in all pools. These data show excellent field performance of the INSTI test, and highlight that this test can be implementedat SA clinics.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6522311PMC
http://dx.doi.org/10.1002/jmv.25447DOI Listing

Publication Analysis

Top Keywords

rapid tests
20
insti test
16
field performance
12
performance insti
12
insti hiv-1/-2
8
hiv-1/-2 antibody
8
test
8
antibody test
8
antenatal clinics
8
naat performed
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!