Background: Pulse diagnosis researches acquiring pulse waves from the wrist radial artery has not yet addressed the issue of whether this information is affected by differences in the hemodynamic characteristics of pressure waves derived from different locations. This study aimed to clarify whether the blood dynamic states are identical with regard to the "three positions and nine indicators" ((Equation is included in full-text article.)) listed in traditional Chinese medicine (TCM).

Methods: A total of 37 participants of CAD group and 20 participants of healthy group were recruited, and pressure pulse waves were measured at 18 locations on both hands. A multivariate analysis (MANOVA) was performed with a "randomized block design" using SPSS 22.0 and R 3.4.1 to examine the time-domain parameters that represented certain hemodynamic characteristics.

Results: In CAD group, the results showed significant differences (p < 0.05) among the h1, h2, h3, h1/t, and h3/h1 measurements of the pulse waves using different indicators at the same position; the h1, h2, h3, and h1/t measurements of the pulse waves at different positions using the indicator "Superficial"; and the h1, h2, h3, h1/t, and h3/h1 measurements of the pulse waves at different positions using the indicator "Medium". In healthy group, the results showed significant differences (p < 0.05) among the h1, h2, h3, and h1/t measurements of the pulse waves using different indicators at the same position; the h1, h2, and h1/t measurements of the pulse waves at different positions using the same indicator.

Conclusion: Because of the differences in the hemodynamic characteristics among the different positions and indicators, the article might provide a new opinion for future pulse diagnosis investigations to carefully consider the measurement location to ensure the completeness of the information.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jcma.2018.07.002DOI Listing

Publication Analysis

Top Keywords

pulse waves
28
measurements pulse
20
pulse diagnosis
12
h1/t measurements
12
waves positions
12
pulse
10
measurement location
8
waves
8
differences hemodynamic
8
hemodynamic characteristics
8

Similar Publications

Magnonics, which harnesses the unique properties of spin waves, offers promising advancements in data processing due to its broad frequency range, nonlinear dynamics, and scalability for on-chip integration. Effective information encoding in magnonic systems requires precise spatial and temporal control of spin waves. Here, we demonstrate the rapid optical control of spin-wave transport in hybrid magnonic-plasmonic structures.

View Article and Find Full Text PDF

The therapeutic potential of extracellular vesicles (EVs) in bone regeneration is noteworthy; however, their clinical application is impeded by low yield and limited efficacy. This study investigated the effect of low-intensity pulsed ultrasound (LIPUS) on the therapeutic efficacy of EVs derived from periodontal ligament stem cells (PDLSCs) and preliminarily explored its mechanism. PDLSCs were cultured with osteogenic media and stimulated with or without LIPUS, and then EVs and LIPUS-stimulated EVs (L-EVs) were isolated separately.

View Article and Find Full Text PDF

Mesoscale heterogeneity is a critical determinant for spiral pattern formation in developing social amoeba.

Sci Rep

January 2025

Institute for Open and Transdisciplinary Research Initiatives, Osaka University, Yamadaoka 2-1, Suita, 565-0871, Osaka, Japan.

Heterogeneity is a critical determinant for multicellular pattern formation. Although the importance of microscale and macroscale heterogeneity at the single-cell and whole-system levels, respectively, has been well accepted, the presence and functions of mesoscale heterogeneity, such as cell clusters with distinct properties, have been poorly recognized. We investigated the biological importance of mesoscale heterogeneity in signal-relaying abilities (excitability) in the self-organization of spiral waves of intercellular communications by studying the self-organized pattern formation in a population of Dictyostelium discoideum cells, a classical signal-relaying system model.

View Article and Find Full Text PDF

Pulsed Ultrasound-Mediated Drug Delivery Enhancement Through Human Sclera.

Transl Vis Sci Technol

January 2025

Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China.

Purpose: The purpose of this study was to characterize whether pulsed ultrasound (PUS) affects transscleral drug delivery.

Methods: Fluorescein sodium (NaF, 376 Da) and fluorescein isothiocyanate-conjugated dextran 40 (FD-40, 40 kDa) were used as model drugs. Human sclera grafts were placed in modified Franz diffusion cells and were treated by PUS (1 megahertz [MHz], 0.

View Article and Find Full Text PDF

Acute Kidney Injury (AKI) is a significant medical condition characterized by the abrupt decline in kidney function.Low-intensity pulsed ultrasound (LIPUS), a non-invasive therapeutic technique employing low-intensity acoustic wave pulses, has shown promise in promoting tissue repair and regeneration. A novel LIPUS system was developed and evaluated in rat AKI models, focusing on its effects on glomerular filtration rate (GFR), blood urea nitrogen (BUN), serum creatinine (SCr), and the Notch1-Akt-eNOS signaling pathway.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!