Sacroiliac joint (SIJ) biomechanics have been described in both in vitro and in vivo studies. A standard for joint coordinate systems has been created by the International Society of Biomechanics for most of the joints in the human body. However, a standardized joint coordinate system for sacroiliac joint motion analysis is currently still lacking. This impedes the comparison across studies and hinders communication among scientists and clinicians. As SIJ motion is reported to be quite limited, a proper standardization and reproducibility of this procedure is essential for the interpretation of future biomechanical SIJ studies. This paper proposes a joint coordinate system for the analysis of sacroiliac joint motion, based on the procedure developed by Grood and Suntay, using semi-automated anatomical landmarks on 3D joint surfaces. This coordinate system offers high inter-rater reliability and aspires to a more intuitive representation of biomechanical data, as it is aligned with SIJ articular surfaces. This study aims to encourage further reflection and debate on biomechanical data representation, in order to facilitate interpretation of SIJ biomechanics and improve communication between researchers and clinicians. © 2019 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jor.24271DOI Listing

Publication Analysis

Top Keywords

joint coordinate
16
coordinate system
16
sacroiliac joint
16
joint
9
analysis sacroiliac
8
sij biomechanics
8
joint motion
8
biomechanical data
8
sij
5
system
4

Similar Publications

In clinical movement biomechanics, kinematic measurements are collected to characterise the motion of articulating joints and investigate how different factors influence movement patterns. Representative time-series signals are calculated to encapsulate (complex and multidimensional) kinematic datasets succinctly. Exacerbated by numerous difficulties to consistently define joint coordinate frames, the influence of local frame orientation and position on the characteristics of the resultant kinematic signals has been previously proven to be a major limitation.

View Article and Find Full Text PDF

Polyvinyl alcohol/chitosan hydrogel based on deep eutectic solvent for promoting methicillin-resistant Staphylococcus aureus-infected wound healing.

Int J Biol Macromol

January 2025

School of Veterinary Medicine, Jiangsu Co-innovation Center for Prevention and Control of Important Animal Infectious Diseases and Zoonoses, Yangzhou University, Yangzhou 225009, PR China; Joint International Research Laboratory of Agriculture and Agri-Product Safety, the Ministry of Education of China, Yangzhou University, Yangzhou, Jiangsu 225009, PR China. Electronic address:

Bacterial-infected wounds usually lead to slow wound healing due to increased inflammation, especially wounds infected by drug-resistant bacteria, which is a serious challenge in the biomedical field. Traditional antimicrobial strategies such as antibiotics lead to a significant increase in drug-resistant strains and have limited efficacy. Therefore, there is an urgent need to develop multifunctional dressings with excellent antibacterial activity and promotion of wound healing.

View Article and Find Full Text PDF

Compared to the general population, individuals with Down syndrome carry a much higher genetic risk of developing early onset Alzheimer's dementia. This leads to unique challenges and the need for a targeted patient journey.In a qualitative interview study with medical professionals, patient organisations and formal and informal care persons, we assessed barriers within the medical care process of this patient group as well as current approaches to overcome these problems.

View Article and Find Full Text PDF

Purpose: To describe a novel alternative technique for C2 fixation under the concept of atlantoaxial joint distraction and fusion with intra-articular Cages, and to report its preliminary clinical outcomes.

Methods: Eighteen patients with basilar invagination and atlantoaxial dislocation underwent atlantoaxial joint distraction and fusion with intra-articular Cages. All patients had hypoplasia of the C2 isthmus prohibiting insertion of the pedicle screw.

View Article and Find Full Text PDF

Objective: While researchers are crucial to the successful delivery of implementation trials, their perspectives are rarely captured in the evaluation of these trials. This qualitative study aimed to capture the experiences of a small research team coordinating a large, multisite implementation trial (the Hide and Seek Project) in the Australian healthcare setting.

Design: A qualitative approach was used, whereby members of the Hide and Seek Project research team were invited to take part in semistructured focus groups led by an external facilitator.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!