Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background Manufacturers of high-sensitivity cardiac troponin (hs-cTn) assays have restricted use of what sample types or matrices are acceptable to use for measurement. Our goal was to evaluate the comparability of the Siemens ADVIA Centaur hs-cTnI assay across different matrices and under different storage conditions. Methods Three different QC-plasma matrices were evaluated for imprecision <10 ng/L. Passing-Bablok regression and difference plots were determined for cTnI concentrations spanning the reference interval (limit of quantification to male 99th-percentile: 2.5 ng/L to <60 ng/L) between serum and lithium heparin plasma, lithium heparin and EDTA plasma and between the Siemens and Abbott hs-cTnI assays. Stability at room temperature (RT) and 2-8 °C was also assessed across the three matrices. Results Over 16-weeks the SDs were ≤1.0 ng/L for QCs ranging from 5.0 to 8.3 ng/L. Across the reference interval there was excellent agreement between lithium heparin plasma and serum for the Siemens hs-cTnI assay (slope=0.98/intercept=-0.1), however, cTnI concentrations were proportionally lower in EDTA as compared to lithium heparin plasma (slope=0.90, 95% CI: 0.88-0.92). In lithium heparin plasma the Siemens hs-cTnI concentrations were higher than the Abbott hs-cTnI concentrations (slope=1.26/intercept=-0.2). Stability of cTnI in lithium heparin plasma as compared in serum and EDTA plasma appeared more labile, with decreases ≥20% in concentrations evident as early as 1-day in storage at RT. Conclusions There is excellent agreement in concentrations between lithium heparin plasma and serum with the Siemens ADVIA Centaur hs-cTnI assay; however, cTnI concentrations in EDTA plasma are lower. Reference intervals and clinical studies in EDTA plasma for the Centaur hs-cTnI assay are required before clinical use.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1515/cclm-2018-1100 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!