A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Fluorometric determination of mercury(II) via a graphene oxide-based assay using exonuclease III-assisted signal amplification and thymidine-Hg(II)-thymidine interaction. | LitMetric

A highly sensitive and selective fluorometric method is described for determination of mercury(II). It is based on (a) the use of graphene oxide (GO) acting as a quencher of the fluoresence of the carboxy-fluorescein (FAM), and (b) of Hg(II)-triggered cleavage of the newly formed nucleic acid sequences harbored blunt 3'-hydroxyl termini by exonuclease III (Exo III) that leads to signal amplification. Two DNA probes are used, viz. a capture probe (CP) and a help probe; HP) that is partially complementary. In the absence of Hg(II), the FAM-labeled hairpin (signal probe, SP) is adsorbed onto the surface of GO via π-stacking interactions. CP blocks the release of the HP for binding to SP. This results in quenching of the green fluorescence of the label. Upon addition of Hg(II), the linear structure of CP is converted to a hairpin structure due to the formation of thymidine-Hg(II)-thymidine duplexes. HP is released from the CP/HP hybrids, and this causes SP to be released from from GO and fluorescence to be recovered. The signal is strongly amplified by using Exo III-assisted targeting and recycling of HP. Hence, Hg(II) can be detected via the strong increase in fluorescence. The method has a linear response in the 0.1 to 30 nM Hg(II) concentration range and a 10 pM detection limit. It was applied to the determination of Hg(II) in three (spiked) Chinese medicines. Graphical abstract Schematic representation of fluorescence sensing strategy for Hg by using graphene oxide as a quencher and exonuclease III-assisted signal amplification.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00604-019-3332-xDOI Listing

Publication Analysis

Top Keywords

signal amplification
12
determination mercuryii
8
exonuclease iii-assisted
8
iii-assisted signal
8
graphene oxide
8
signal
5
hgii
5
fluorometric determination
4
mercuryii graphene
4
graphene oxide-based
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!