Background: Body surface area (BSA) can reflect metabolic rate that might normalize dosing of chemotherapeutics across widely variable weights within a species. The current BSA formula for dogs lacks height, length, and body condition.
Hypothesis: Computed tomography (CT) imaging will allow inclusion of morphometric variables in allometric modeling of BSA in dogs resulting in an improved formula for BSA estimation.
Animals: Forty-eight dogs from 4 institutions with whole-body CT images.
Methods: Retrospective and prospective case series. Body surface area was contoured using whole-body CT scans and radiation therapy planning software. Body length and height were determined from CT images and also in 9 dogs by physical measurement. Nonlinear regression was used to model the BSA data sets using allometric equations. Goodness-of-fit criteria included average relative deviation, mean standard error, Akaike information criterion, and r (derived from the r-value generated by regression models).
Results: Contoured BSA differed from the current formula by -9% to +19%. Nonlinear regression on untransformed data yielded BSA = 0.0134 × body weight [kg] 0.4746 × length (cm) 0.6393 as the best-fit model. Heteroscedasticity (increasing morphometric variability with increasing BSA) was an important finding.
Conclusions And Clinical Importance: Computed tomography-derived BSA was used to incorporate body length into a novel BSA formula. This formula can be applied prospectively to determine whether it correlates with adverse events attributed to chemotherapy.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6430937 | PMC |
http://dx.doi.org/10.1111/jvim.15440 | DOI Listing |
ACS Appl Mater Interfaces
January 2025
Department of Chemistry and Biochemistry, University of California Santa Barbara, Santa Barbara, California 93106, United States.
Electrochemical aptamer-based (EAB) sensors are a molecular measurement platform that enables the continuous, real-time measurement of a wide range of drugs and biomarkers in situ in the living body. EAB sensors are fabricated by depositing a thiol-modified, target-binding aptamer on the surface of a gold electrode, followed by backfilling with an alkanethiol to form a self-assembled monolayer. And while the majority of previously described EAB sensors have employed hydroxyl-terminated monolayers, a handful of studies have shown that altering the monolayer headgroup can strongly affect sensor performance.
View Article and Find Full Text PDFInhal Toxicol
January 2025
Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Morgantown, WV, USA.
: Pulmonary exposure to emissions from manipulating solid surface composite (SSC) materials has been associated with adverse health effects in humans and laboratory animals. Previous and investigations of SSC toxicity have been limited by particle delivery methods that do not fully recapitulate the workplace environment. This study sought to determine the acute SSC-induced pulmonary responses whole-body inhalation exposure.
View Article and Find Full Text PDFProtein Sci
February 2025
Department of Biochemistry and Molecular Biology, Michigan State University, East Lansing, Michigan, USA.
The TGF-β family ligand Nodal is an essential regulator of embryonic development, orchestrating key processes such as germ layer specification and body axis formation through activation of SMAD2/3-mediated signaling. Significantly, this activation requires the co-receptor Cripto-1. However, despite their essential roles in embryogenesis, the molecular mechanism through which Cripto-1 enables Nodal to activate the SMAD2/3 pathway has remained elusive.
View Article and Find Full Text PDFBiopolymers
March 2025
Department of Chemical and Materials Engineering, University of Alberta, Alberta, Canada.
When the kidneys are injured, uremic toxins (UTXs) accumulate in the body, affecting other tissues and causing a loss of essential body functions. This study investigated the adsorption of blood plasma-laden UTXs on the surface of PCL fibers to assess their potential as an alternative to membrane dialysis materials. Using plasma containing 26 UTXs at a concentration similar to that found in end-stage kidney disease patients, we analyzed the adsorbed proteins and examined clot formation in normal and toxin-treated plasma in the presence of PCL fibers.
View Article and Find Full Text PDFJ Ophthalmol
January 2025
Departments of Genetics, Microbiology and Immunology, Center for Research on Harmful Effects of Biological and Chemical Hazards, Faculty of Medical Sciences University of Kragujevac, 69 Svetozara Markovica Street, Kragujevac 34000, Serbia.
Severe dry eye disease (DED) is an inflammatory condition characterized by a lack of sufficient moisture or lubrication on the surface of the eye, significantly impacting the quality of life and visual function. Since detrimental immune response is crucially responsible for the development and aggravation of DED, therapeutic agents which modulate phenotype and function of eye-infiltrated inflammatory immune cells could be used for the treatment of severe DED. Due to their potent immunomodulatory properties, mesenchymal stem cells (MSCs) represent potentially new remedies for the treatment of inflammatory eye diseases.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!