Deep peroneal nerve has a potential risk of injury during open-wedge high tibial osteotomy.

Knee Surg Sports Traumatol Arthrosc

Department of Orthopaedic Surgery, Tokyo Women's Medical University, 8-1 Kawada-cho, Shinjuku-ku, Tokyo, 162-8666, Japan.

Published: May 2020

Purpose: To assess the risk of injury to the neurovascular bundle on the interosseous membrane of the leg during drilling for distal screw insertion in open-wedge high tibial osteotomy (OWHTO), and to investigate the possible influence of the method of plate placement on the risk.

Methods: This retrospective study involved, 55 patients (32 with a TomoFix plate, 23 with a TriS plate) who underwent postoperative CT scanning of the knee following OWHTO between 2009 and 2018. The angle and position of the locking plate, and the direction of screw insertion relative to the interosseous membrane were analysed.

Results: All distal screws had a risk of neurovascular injury. In particular, 25 screws at the #4 hole (45%) had an extended insertion trajectory that intersected with the interosseous membrane. The angle of the proximal part of the TomoFix plate was a significant risk factor. In contrast, methods of TriS plate placement showed no statistically significant differences.

Conclusions: Extended insertion trajectories of distal screws were likely to intersect with the interosseous membrane with the neurovascular bundle potentially on its surface; thus, drilling for bicortical fixation posed a risk of neurovascular injury. The risk increased as the TomoFix plate was placed more medially, suggesting that bicortical drilling must be performed with the utmost attention when the plate is placed at the medial position. Given the particularly high risk at the #3 and #4 screw holes, monocortical fixation of a few distal screws is recommended as long as good stability is ensured.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00167-019-05445-yDOI Listing

Publication Analysis

Top Keywords

interosseous membrane
16
tomofix plate
12
distal screws
12
risk injury
8
open-wedge high
8
high tibial
8
tibial osteotomy
8
neurovascular bundle
8
screw insertion
8
plate
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!