Development of electroforming process for soft x-ray ellipsoidal mirror. | LitMetric

Development of electroforming process for soft x-ray ellipsoidal mirror.

Rev Sci Instrum

Department of Precision Engineering, Graduate School of Engineering, The University of Tokyo, 7-3-1 Bunkyo-ku, Hongo, Tokyo 113-0033, Japan.

Published: February 2019

AI Article Synopsis

  • An x-ray ellipsoidal mirror is crucial for focusing soft x-rays, but creating one with the required nanometer-level accuracy is challenging, especially for small diameters.* -
  • Researchers developed a method to fabricate these mirrors using nickel sulfamate electroforming on a high-precision quartz mandrel that has the mirror's inverted shape.* -
  • A mirror measuring 40-mm in length was created, showing a replication error of 27.2 nm overall and 14.7 nm in the central area, enabling the potential to focus soft x-rays down to a 400 nm diameter spot.*

Article Abstract

An x-ray ellipsoidal mirror is an ideal tool for focusing soft x-rays. Because nanometer-level shape accuracy is required in the internal surface of a mirror having a small diameter, it is difficult to fabricate the mirror by processing the surface directly. We developed a fabrication process for soft x-ray ellipsoidal mirrors in which the surface of a high-precision quartz mandrel with the inverted shape of the designed mirror is replicated by nickel sulfamate electroforming. In this study, an ellipsoidal mirror of 40-mm length was fabricated and the shape accuracy of the replicated surface was evaluated by a measurement method using a contact probe. The root mean square (RMS) of the replication error in the entire measured surface was 27.2 nm. When the evaluated area was half the replicated surface near the middle of the mirror, the RMS of the replication error was 14.7 nm. Wave-optical simulation suggested that it is possible to focus soft x-rays to a spot with a diameter of 400 nm.

Download full-text PDF

Source
http://dx.doi.org/10.1063/1.5057432DOI Listing

Publication Analysis

Top Keywords

x-ray ellipsoidal
12
ellipsoidal mirror
12
process soft
8
soft x-ray
8
soft x-rays
8
shape accuracy
8
replicated surface
8
rms replication
8
replication error
8
mirror
7

Similar Publications

Structural, morphological, mechanical, and electrical studies of N. nucifera fibres.

Int J Biol Macromol

December 2024

Center for Material Science, Vijnana Bhavan, Manasagangotri, University of Mysore, Mysuru 570017, India.

The Powder X-ray diffraction (PXRD) data of Nelumbo Nucifera fibre is utilized to study multifaceted properties. Rietveld refinement was carried out along with cellulose phase. The crystallite size was computed using the Scherrer equation, and through first principle calculations, it has been illustrated and concluded that the size is not ellipsoidal, as previously suggested by other researchers; rather, it exhibits a multidimensional shape.

View Article and Find Full Text PDF

The morphology of an individual particulate refers to its shape characteristics and size properties, which both play important roles for granular matter in physics, mechanics, chemistry, and biology. In this study, ellipsoidality is defined as a 3D shape index for evaluating particle roundness, and an explicit calculation method is applied. The dependences of 3D shape characteristics (aspect ratios, sphericity, and ellipsoidal degree) on particle size (ranges from 0.

View Article and Find Full Text PDF

Worm-like Micelle Formation of Sugar-Based Nonionic Surfactant with Multibranched Methyl Chains.

Langmuir

December 2024

Department of Chemistry, Faculty of Science, Nara Women's University, Kitauoyanishi-machi, Nara 630-8506, Japan.

The aggregation properties of sugar-based surfactants with methyl groups at multiple positions on the linear alkyl chain are an understudied topic. Therefore, in this study, we performed a structural analysis of aggregates formed by two types of sugar-based nonionic surfactants with multibranched methyl chains, 3,7,11-trimethyldodecyl maltoside (CMal), as well as with a linear chain, dodecyl--d-maltoside (CMal), in aqueous solutions using rheological and small-angle X-ray scattering techniques. CMal showed an excellent performance in lowering surface tension (28.

View Article and Find Full Text PDF

Impact of Discordance Between MRI and US Volume Measurements on Prostate Fusion Biopsy Outcomes.

J Urol

December 2024

Center for Interventional Oncology, Radiology and Imaging Sciences, Clinical Center, National Institutes of Health, Bethesda, MD 20892, USA.

Purpose: To determine whether the difference between MRI-based and ultrasound (US)-based volume measurements are associated with MRI/US-targeted fusion-guided biopsy outcomes.

Materials And Methods: This retrospective, single-center study involved 4177 consecutive patients biopsied between 2010 and 2023 using both MRI/US-targeted fusion and systematic biopsy. Biopsies were indicated because of elevated prostate-specific antigen levels or abnormal multiparametric MRI results.

View Article and Find Full Text PDF

Acute retinal pigment epitheliitis using adaptive optics imaging: a case report.

BMC Ophthalmol

November 2024

Department of Ophthalmology, Erasmus MC, University Medical Center, Rotterdam, The Netherlands.

Article Synopsis
  • Acute Retinal Pigment Epitheliitis (ARPE) is a rare eye disorder mostly affecting young adults, leading to temporary vision loss, often resolving within 6 to 12 weeks.
  • The condition was studied in two patients using advanced imaging techniques like Optical Coherence Tomography (OCT) and Adaptive Optics Flood Illumination Ophthalmoscopy (AO-FIO), revealing insights into retinal changes and recovery.
  • Both patients showed initial vision loss but eventually regained eyesight, although some retinal structural changes persisted even after improvement, highlighting the disease's complex nature.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!