An x-ray ellipsoidal mirror is an ideal tool for focusing soft x-rays. Because nanometer-level shape accuracy is required in the internal surface of a mirror having a small diameter, it is difficult to fabricate the mirror by processing the surface directly. We developed a fabrication process for soft x-ray ellipsoidal mirrors in which the surface of a high-precision quartz mandrel with the inverted shape of the designed mirror is replicated by nickel sulfamate electroforming. In this study, an ellipsoidal mirror of 40-mm length was fabricated and the shape accuracy of the replicated surface was evaluated by a measurement method using a contact probe. The root mean square (RMS) of the replication error in the entire measured surface was 27.2 nm. When the evaluated area was half the replicated surface near the middle of the mirror, the RMS of the replication error was 14.7 nm. Wave-optical simulation suggested that it is possible to focus soft x-rays to a spot with a diameter of 400 nm.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1063/1.5057432 | DOI Listing |
Int J Biol Macromol
December 2024
Center for Material Science, Vijnana Bhavan, Manasagangotri, University of Mysore, Mysuru 570017, India.
The Powder X-ray diffraction (PXRD) data of Nelumbo Nucifera fibre is utilized to study multifaceted properties. Rietveld refinement was carried out along with cellulose phase. The crystallite size was computed using the Scherrer equation, and through first principle calculations, it has been illustrated and concluded that the size is not ellipsoidal, as previously suggested by other researchers; rather, it exhibits a multidimensional shape.
View Article and Find Full Text PDFMaterials (Basel)
November 2024
Key Laboratory of Highway Engineering of Ministry of Education, Changsha University of Science & Technology, Changsha 410114, China.
The morphology of an individual particulate refers to its shape characteristics and size properties, which both play important roles for granular matter in physics, mechanics, chemistry, and biology. In this study, ellipsoidality is defined as a 3D shape index for evaluating particle roundness, and an explicit calculation method is applied. The dependences of 3D shape characteristics (aspect ratios, sphericity, and ellipsoidal degree) on particle size (ranges from 0.
View Article and Find Full Text PDFLangmuir
December 2024
Department of Chemistry, Faculty of Science, Nara Women's University, Kitauoyanishi-machi, Nara 630-8506, Japan.
The aggregation properties of sugar-based surfactants with methyl groups at multiple positions on the linear alkyl chain are an understudied topic. Therefore, in this study, we performed a structural analysis of aggregates formed by two types of sugar-based nonionic surfactants with multibranched methyl chains, 3,7,11-trimethyldodecyl maltoside (CMal), as well as with a linear chain, dodecyl--d-maltoside (CMal), in aqueous solutions using rheological and small-angle X-ray scattering techniques. CMal showed an excellent performance in lowering surface tension (28.
View Article and Find Full Text PDFJ Urol
December 2024
Center for Interventional Oncology, Radiology and Imaging Sciences, Clinical Center, National Institutes of Health, Bethesda, MD 20892, USA.
Purpose: To determine whether the difference between MRI-based and ultrasound (US)-based volume measurements are associated with MRI/US-targeted fusion-guided biopsy outcomes.
Materials And Methods: This retrospective, single-center study involved 4177 consecutive patients biopsied between 2010 and 2023 using both MRI/US-targeted fusion and systematic biopsy. Biopsies were indicated because of elevated prostate-specific antigen levels or abnormal multiparametric MRI results.
BMC Ophthalmol
November 2024
Department of Ophthalmology, Erasmus MC, University Medical Center, Rotterdam, The Netherlands.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!