A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Utility of the Medtronic microvascular plug™ as a transcatheter implantable and explantable pulmonary artery flow restrictor in a swine model. | LitMetric

Background: A surgical pulmonary artery band (PAB) is used to control excessive pulmonary blood flow for certain congenital heart diseases. Previous attempts have been made to develop a transcatheter, implantable pulmonary flow restrictor (PFR) without great success. We modified a microvascular plug (MVP) to be used as a PFR. The objectives of this study were to demonstrate feasibility of transcatheter implantation and retrieval of the modified MVP as a PFR, and compare PA growth while using the PFR versus PAB.

Methods And Results: The PFR was implanted in eight newborn piglets in bilateral branch pulmonary arteries (PAs). Immediately post-PFR implantation, the right ventricular systolic pressure increased from a median of 20-51 mmHg. Transcatheter retrieval of PFR was 100% successful at 3, 6, and 9 weeks and 50% at 12-weeks post-implant. A left PAB was placed via thoracotomy in four other newborn piglets. Debanding was performed 6-weeks later via balloon angioplasty. On follow-up, the proximal left PA diameters in the PFR and the PAB groups were similar (median 8 vs. 7.1 mm; p = 0.11); albeit the surgical band sites required repeat balloon angioplasty secondary to recurrent stenosis. By histopathology, there was grade II vessel injury in two pigs immediately post-retrieval of PFR that healed by 12 weeks.

Conclusions: Transcatheter implantation and retrieval of the MVP as a PFR is feasible. PA growth is comparable to surgical PAB, which is likely to require reinterventions. The use of the MVP as a PFR in humans has to be trialed before recommending its routine use.

Download full-text PDF

Source
http://dx.doi.org/10.1002/ccd.28162DOI Listing

Publication Analysis

Top Keywords

mvp pfr
16
pfr
10
transcatheter implantable
8
pulmonary artery
8
flow restrictor
8
transcatheter implantation
8
implantation retrieval
8
newborn piglets
8
balloon angioplasty
8
transcatheter
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!