Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Calprotectin is a calcium- and zinc-binding protein of the S-100 protein family which is mainly found within neutrophils and throughout the human body. The presence of calprotectin in faeces is a consequence of neutrophil migration into the gastrointestinal tissue due to an inflammatory process. Faecal calprotectin concentrations demonstrate good correlation with intestinal inflammation and faecal calprotectin is used as a biomarker in gastrointestinal disorders. Faecal calprotectin is a very sensitive marker for inflammation in the gastrointestinal tract, and useful for the differentiation of inflammatory bowel disease (IBD) from irritable bowel syndrome (IBS). Faecal calprotectin is used for the diagnosis, monitoring disease activity, treatment guidance and prediction of disease relapse and post-operative recurrence in IBD. There may also potentially be a role for faecal calprotectin in the management of infectious gastroenteritis, acute appendicitis, peptic ulcer disease, cystic fibrosis, coeliac disease, transplant rejection and graft versus host disease. Further studies are needed to confirm its utility in these conditions. Analysis of faecal calprotectin consists of an extraction step followed by quantification by immunoassay. Over the past few decades, several assays and extraction devices including point-of-care methods have been introduced by manufacturers. The manufacturer-quoted cut-off values for different faecal calprotectin assays are generally similar. However, the sensitivities and specificities at a given cut-off, and therefore the optimum cut-off values, are different between assays. A reference standard for calprotectin is lacking. Therefore, assay standardisation is required for more accurate and traceable test results for faecal calprotectin.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6370282 | PMC |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!