Background: In the application of scientific human skeletal variation in medico-legal matters, virtual anthropology is the current technique performed to examine skeleton and its body parts. Hence, this study was conducted to assess the accuracy and reliability of virtual femur measurement through intra and inter-observer error analysis, and comparison was made between the virtual and conventional methods.

Methods: A total of 15 femora were examined with four parameters i.e. maximum length of femur (FeMl), diameter of femoral head (FeHd), transverse diameter of midshaft (FeMd) and condylar breadth (FeCb). Osteometric board and vernier calipers were employed for the conventional method, while CT reconstructed images and Osirix MD software was utilised for the virtual method.

Results: Results exhibited that there were no significant differences in the measurements by conventional and virtual methods. There were also no significant differences in the measurements by the intra or inter-observer error analyses. The intraclass correlation coefficients (ICC) were more than 0.95 by both intra and inter-observer error analyses. Technical error of measurement had displayed values within the acceptable ranges (rTEM <0.08 for intra-observer, <2.25 for inter-observer), and coefficient of reliability (R) indicated small measurement errors (R > 0.95 for intra-observer, R > 0.92 for inter-observer). By parameters, FeMl showed the highest R value (0.99) with the least error in different methods and observers (rTEM = 0.02-0.41%). Bland and Altman plots revealed points scattered close to zero indicating perfect agreement by both virtual and conventional methods. The mean differences for FeMl, FeHd, FeMd and FeCb measurements were 0.01 cm, -0.01 cm, 0.02 cm and 0.01 cm, respectively.

Conclusion: This brought to suggest that bone measurement by virtual method was highly accurate and reliable as in the conventional method. It is recommended for implementation in the future anthropological studies especially in countries with limited skeletal collection.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jflm.2019.02.010DOI Listing

Publication Analysis

Top Keywords

intra inter-observer
12
inter-observer error
12
accuracy reliability
8
virtual
8
reliability virtual
8
virtual femur
8
femur measurement
8
virtual conventional
8
conventional method
8
differences measurements
8

Similar Publications

Background: The Bethesda System for Reporting Thyroid Cytology (TBSRTC) recommended for the interpretation of needle aspiration cytology of the thyroid, is the most widely used worldwide. Studies have shown that the disagreement between observers, especially in the Bethesda III and IV diagnostic categories, is not insignificant at 10%-40%. In the TBSRTC 2023 version, some definitions were removed and simplified, and molecular pathology was proposed as a complement to cytopathology.

View Article and Find Full Text PDF

Defining Normal Enthesis Stiffness Range in A Healthy Adult Population.

Br J Radiol

December 2024

Rheumatology Unit, Department of Internal Medicine, Faculty of Medicine, Universiti Teknologi MARA, 47000, Sungai Buloh, Malaysia.

Objectives: This study explores the correlation between volunteer demographics with enthesis stiffness and intra and inter -observer agreements using shear wave elastography (SWE).

Methods: 98 healthy volunteers were recruited. SWE was performed on quadriceps, suprapatellar, infrapatellar, and Achilles entheses.

View Article and Find Full Text PDF

Objectives: The enormous burden that cardiovascular diseases put on individuals and societies warrants reliable biomarkers of disease risk to optimize disease prevention. We studied longitudinal movement (LMov) in arterial walls using ultrasound of the common carotid artery (CCA). We believe that LMov could be a sensitive biomarker of cardiovascular health and in this study, we evaluate the intra-observer repeatability and inter-observer precision of our method.

View Article and Find Full Text PDF

Reviewing the reliability of revised Melbourne Cerebral Palsy Hip Classification System across different medical specialties.

Jt Dis Relat Surg

January 2025

Adnan Menderes Üniversitesi Tıp Fakültesi Ortopedi ve Travmatoloji Anabilim Dalı, 09010 Efeler, Aydın, Türkiye.

Objectives: The aim of this study was to measure the reliability of the expanded and revised Melbourne Cerebral Palsy Hip Classification System (r-MCPHCS) across different medical specialties.

Patients And Methods: Anteroposterior pelvic radiographs of a total of 44 patients (20 males, 24 females; median 16.7 years; range, 12 to 32 years) with cerebral palsy (CP) were analyzed between January 2005 and December 2020.

View Article and Find Full Text PDF

Observer reliability in counting erythrocyte ghost cells and impact of short-term storage of canine and feline blood samples.

Vet J

December 2024

Department of Veterinary Clinical Sciences, Faculty of Health and Medical Sciences, University of Copenhagen, Dyrlaegevej 16, Frederiksberg C DK-1870, Denmark.

The presence of erythrocyte ghost cells (EG) in blood smears indicates intravascular haemolysis or in-vitro haemolysis. However, observer reliability in detection of EG has not been documented. Immediate blood smear preparation is advised but may not always be practical.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!