Transoral robotic surgery (TORS) is a common modality for treatment of oropharyngeal and laryngeal cancer. Current FDA approval extends to the da Vinci S and Si platforms. Many hospitals are adopting the da Vinci Xi platform. Reports of head and neck surgical outcomes with this platform are scant. This study reports outcomes of TORS procedures performed with the da Vinci Xi platform including perioperative adverse events, functional outcomes, and short-term local control. A retrospective review of TORS performed with the da Vinci Xi platform is undertaken. Twenty-two consecutive TORS cases with the Xi platform are reviewed. Procedures performed include radical tonsillectomy, base of tongue resection, and lingual tonsillectomy. Two bleeding events occurred (9% of cases), both of intermediate severity as per Mayo criteria. Three procedures resulted in positive margin status, early in the case series, and two were cleared with revision resection. One-year local control rate, where available, is 100%. There were no perioperative deaths, long-term gastrostomy dependence, or performance of tracheostomy. Advantages of this platform include ease of robot deployment and setup. Disadvantages include increased width of instrumentation compared with previous platforms with crowding of access. The availability of a specific robotic platform may be dictated by hospital-wide policy across service lines. This report suggests that the da Vinci Xi permits performance of TORS with safety and oncologic outcomes similar to previous platforms; however, long-term follow-up is needed.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s11701-019-00938-xDOI Listing

Publication Analysis

Top Keywords

vinci platform
16
transoral robotic
8
robotic surgery
8
platform
8
procedures performed
8
performed vinci
8
local control
8
previous platforms
8
vinci
6
tors
5

Similar Publications

Colloidal solids (COLIS) is a state-of-the-art light scattering setup developed for experiments onboard the International Space Station (ISS). COLIS allows for probing the structure and dynamics of soft matter systems on a wide range of length scales, from a few nm to tens of microns, and on time scales from 100 ns to tens of hours. In addition to conventional static and dynamic light scattering, COLIS includes depolarized dynamic light scattering, a small-angle camera, photon correlation imaging, and optical manipulation of thermosensitive samples through an auxiliary near-infrared laser beam, thereby providing a unique platform for probing soft matter systems.

View Article and Find Full Text PDF

Introduction: We describe a method of robotic ureterocalicostomy (RALUC) with the Da Vinci Single Port (SP) platform and present clinical outcomes in our cohort of patients.

Materials And Methods: We retrospectively reviewed all patients undergoing RALUC with the SP platform in a single-institution, IRB-approved database between 2020-2023. Demographics, preoperative, intraoperative, and postoperative outcomes were collated.

View Article and Find Full Text PDF

Objectives: Transoral robotic surgery (TORS) for benign glottic conditions is scarcely represented in the literature. We aimed in this study to report on the technical feasibility of an explicitly transoral robotic approach for a patient with posterior glottic stenosis, and to highlight extant limitations in exposure and robotic instrumentation of the glottis.

Methods: Retrospective chart review of a single patient undergoing a TORS approach to maximize the posterior glottic aperture.

View Article and Find Full Text PDF

Objective: To compare the outcomes of vesicovaginal fistula (VVF) repair using two different robotic systems.

Design: This retrospective comparative study analysed the surgical outcomes of VVF repair utilizing two different robotic platforms: the Hugo RAS Medtronic robot and the da Vinci Xi robot.

Methods: VVF repair was performed with da Vinci Xi system (n = 15) and Hugo RAS Medtronic robot (n = 11) in a non-randomized fashion.

View Article and Find Full Text PDF

Aim: Minimally invasive transanal platforms are now the standard of care for select low-risk rectal tumours. However, existing platforms come with persistent technical challenges. The da Vinci SP Surgical System™ offers a new alternative designed to work effectively in narrow spaces.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!