Ultrasound is a prominent nondestructive testing modality for the detection, localization, and sizing of defects in engineering materials. Often, inspectors analyze ultrasonic waveforms to determine if echoes, which stem from the scattering of ultrasound from a defect, exceed a threshold value. In turn, the initial selection of the threshold value is critical. In this letter, a time-dependent threshold or upper bound for the signal envelope is developed based on the statistics governing the scattering of ultrasound from microstructure. The utility of the time-dependent threshold is demonstrated using experiments conducted on sub-wavelength artificial defects. The results are shown to enhance current nondestructive inspection practices.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1121/1.5089826 | DOI Listing |
Proc Inst Mech Eng H
January 2025
Department of Medical Sciences & Technology, IIT Madras, Chennai, Tamil Nadu, India.
The use of ultrasound contrast agents (UCAs) for estimating portal pressure has recently gained attention due to its clinical promise, yet variability in acoustic amplitude poses challenges. UCAs contain microbubbles (1-10 µm in diameter), and understanding their acoustic response is essential to address this variability. However, systematic exploration of factors influencing microbubble behavior remains limited in current literature.
View Article and Find Full Text PDFBMC Infect Dis
January 2025
Department of Oncology, General Hospital of Western Theatre Command, No. 270, Tianhui Road, Rongdu Avenue, Jinniu District, Chengdu, Sichuan, 610000, People's Republic of China.
Background: Nocardia are widely present in nature and considered opportunistic pathogens. They can result in hematogenous spread infection through the ruptured skin or respiratory tract when the host's immune system is compromised. Currently, 119 species of Nocardia have been identified, with 54 capable of causing infections in humans.
View Article and Find Full Text PDFBioengineering (Basel)
December 2024
Department of Biomedical Engineering, Boston University, Boston, MA 02215, USA.
To optimize microbubble formulations for clinical applications, the size distribution, concentration, and acoustic intensity must be rapidly measurable to allow for the successful iteration of microbubble design. In this paper, a comprehensive method was developed to compare microbubble formulations with different lipid shell compositions using optical and acoustic methods of measurement to collect the size distribution, concentration, and mean scattering intensity. An open-source ImageJ macro code was modified for the selective counting and sizing of brightfield microbubble images.
View Article and Find Full Text PDFJ Cardiothorac Surg
January 2025
Department of Cardiothoracic Surgery, Aalborg University Hospital, Hobrovej 18-22, Aalborg, 9000, Denmark.
Background: The outcome of coronary artery bypass grafting (CABG) depends on several factors, including the quality of the distal anastomoses to the coronary arteries. Early graft failure may be caused by, e.g.
View Article and Find Full Text PDFInt J Biol Macromol
January 2025
College of Food Science, Northeast Agricultural University, Harbin, Heilongjiang 150030, China. Electronic address:
In this study, the improvement mechanism of yeast proteins (YPs) with the ultrasonic and pH shifting treatment on the emulsion stability was investigated through the solubility, protein structure and interface behavior of YPs. Compared with only pH shifting or ultrasound treatment, the solubility of YPs with the combined treatment of ultrasonic and pH shifting was increased significantly. The soluble protein content of pH-U400 reached 85.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!