A cloud-based software, VirtualDose-IR (Virtual Phantoms Inc., Albany, New York, USA), designed to report organ doses and effective doses for a diverse patient population from interventional radiology (IR) procedures has been developed and tested. This software is based on a comprehensive database of Monte Carlo-generated organ dose built with a set of 21 anatomically realistic patient phantoms. The patient types included in this database are both male and female people with different ages reflecting reference adults, obese people with different BMIs and pregnant women at different gestational stages. Selectable parameters such as patient type, tube voltage, filtration thickness, beam direction, field size, and irradiation site are also considered in VirtualDose-IR. The software has been implemented using the 'Software as a Service (SaaS)' delivery concept permitting simultaneous multi-user, multi-platform access without requiring local installation. The patient doses resulting from different target sites and patient populations were reported using the VirtualDose-IR system. The patient doses under different source to surface distances (SSD) and beam angles calculated by VirtualDose-IR and Monte Carlo simulations were compared. For most organs, the dose differences between VirtualDose-IR results and Monte Carlo results were less than 0.3 mGy at 15 000 mGy * cm kerma-area product (KAP). The organ dose results were compared with measurement data previously reported in literatures. The doses to organs that were located within the irradiation field match closely with experimental measurement data. The differences in the effective dose values between calculated using VirtualDose-IR and those measured were less than 2.5%. The dose errors of most organs between VirtualDose-IR and literature results were less than 40%. These results validate the accuracy of organ doses reported by VirtualDose-IR. With the inclusion of pre-specified clinical IR examination parameters (such as beam direction, target location, field of view and beam quality) and the latest anatomically realistic patient phantoms in Monte Carlo simulations, VirtualDose-IR provides users with accurate dose information in order to systematically compare, evaluate, and optimize IR plans.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7480071PMC
http://dx.doi.org/10.1088/1361-6560/ab0bd5DOI Listing

Publication Analysis

Top Keywords

organ doses
12
monte carlo
12
virtualdose-ir
10
cloud-based software
8
interventional radiology
8
patient
8
organ dose
8
anatomically realistic
8
realistic patient
8
patient phantoms
8

Similar Publications

[Investigation of general toxic effects of Relatox in comparison with Dysport].

Zh Nevrol Psikhiatr Im S S Korsakova

December 2024

OOO NBC «Pharmbiomed», Moscow, Russia.

Objective: To evaluate the toxic effects of the agent Relatox on mature outbred rats and mice in an acute experiment in comparison with the registered analogue Dysport.

Material And Methods: Based on the aim of experiment, the acute toxic effects of Relatox and Dysport were assessed on two animal species: rats and mice at intraperitoneal and intramuscular administration at dose levels that made it possible to calculate the toxicological parameter values (initially 10-150 U/kg with subsequent usage of additional doses 20 U/kg to 300 U/kg depending on the agent and route of administration). The LD values and other acute toxic parameters were calculated using probit analysis.

View Article and Find Full Text PDF

Ecotoxicity of Biodegradable Microplastics and Bio-based Microplastics: A Review of in vitro and in vivo Studies.

Environ Manage

December 2024

College of Natural Resources and Environment, Northwest A&F University, Yangling, Shaanxi Province, 712100, PR China.

As biodegradable and bio-based plastics increasingly replace conventional plastics, the need for a comprehensive understanding of their ecotoxicity becomes more pressing. This review systematically presents the ecotoxicity of the microplastics (MPs) from different biodegradable plastics and bioplastics on various animals and plants. High doses of polylactic acid (PLA) MPs (10%) have been found to reduce plant nitrogen content and biomass, and affect the accumulation of heavy metals in plants.

View Article and Find Full Text PDF

Purpose: Long axial field-of-view (LAFOV) positron emission tomography/computed tomography (PET/CT) scanners enable high sensitivity and wide anatomical coverage. Therefore, they seem ideal to perform post-selective internal radiation therapy (SIRT) Y scans, which are needed, to confirm that the dose is delivered to the tumors and that healthy organs are spared. However, it is unclear to what extent the use of LAFOV PET is feasible and which dosimetry approaches results in accurate measurements.

View Article and Find Full Text PDF

Safety assessment on CBD-rich hemp extract in sub-chronic cross-sex study with rats.

Toxicol Appl Pharmacol

December 2024

Department of Medical Chemistry and Biochemistry, Faculty of Medicine and Dentistry, Palacky University, Hnevotinska 3, 775 15 Olomouc, Czech Republic. Electronic address:

Cannabidiol (CBD) is a phytocannabinoid from Cannabis sativa L., in which there is currently growing interest for medicinal use. Here, we focused on the safety and pharmacokinetics of a CBD-rich (77 %, w/w) full-spectrum hemp extract in male and female rats.

View Article and Find Full Text PDF

Dried blood spot LC-MS/MS quantification of voclosporin in renal transplant recipients using volumetric dried blood spot sampling.

J Pharm Biomed Anal

December 2024

Department of Clinical Pharmacy and Toxicology, Leiden University Medical Center, Leiden, the Netherlands; Leiden Network for Personalized Medicine, Leiden, the Netherlands. Electronic address:

Voclosporin is a potent immunosuppressive agent currently approved for treating active lupus nephritis. Based on its potential antiviral activity, it has also been investigated as immunosuppressive agent in an investigator-initiated study in SARS-CoV2 positive kidney transplant recipients. As with many immunosuppressive agents, optimizing dosing regimens to achieve therapeutic efficacy while minimizing toxicity remains a critical challenge in clinical practice.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!