Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: The pacemaker (PM) and implantable cardioverter-defibrillator (ICD) Registry of the Italian Association of Arrhythmology and Cardiac Pacing (AIAC) monitors the main epidemiological data in real-world practice. The survey for the 2017 activity collects information about demographics, clinical characteristics, main indications for PM/ICD therapy and device types from the Italian collaborating centers.
Methods: The Registry collects prospectively national PM and ICD implantation activity on the basis of European cards.
Results: PM Registry: data about 23 457 PM implantations were collected (19 378 first implant and 4079 replacements). The number of collaborating centers was 185. Median age of treated patients was 81 years (75 quartile I; 86 quartile III). ECG indications included atrioventricular conduction disorders in 37.1% of first PM implants, sick sinus syndrome in 19.5%, atrial fibrillation plus bradycardia in 13.2%, other in 30.2%. Among atrioventricular conduction defects, third-degree atrioventricular block was the most common type (21.0% of first implants). Use of single-chamber PMs was reported in 25.6% of first implants, of dual-chamber PMs in 66.7%, of PMs with cardiac resynchronization therapy (CRT) in 1.4%, and of single lead atrial-synchronized ventricular stimulation (VDD/R PMs) in 6.3%. ICD Registry: data about 19 023 ICD implantations were collected (13 898 first implants and 5125 replacements). The number of collaborating centers was 437. Median age of treated patients was 71 years (63 quartile I; 78 quartile III). Primary prevention indication was reported in 81.8% of first implants, secondary prevention in 18.2% (cardiac arrest in 6.4%). A single-chamber ICD was used in 27.0% of first implants, dual-chamber in 33.6% and biventricular in 39.3%.
Conclusions: The PM and ICD Registry appears fundamental for monitoring PM and ICD utilization on a large national scale with rigorous examination of demographics and clinical indications. The PM Registry showed stable electrocardiographic and symptom indications, with an important prevalence of dual-chamber pacing. The use of CRT-PM regards a very limited number of patients. The ICD Registry documented a large use of prophylactic and biventricular ICD, reflecting a favorable adherence to trials and guidelines in clinical practice. In order to increase and optimize the cooperation of Italian implanting centers, online data entry (http://www.aiac.it/riprid) should be adopted at large scale.