Purpose: One of the main problems of knee replacement is the limit of knee flexion. This study focuses on the knee implant and the patellar component currently in use in total knee arthroplasty, analyzing the influence of patellar thickness on the degree of knee flexion following surgery.

Methods: A kinematics study was performed to evaluate whether an optimal patellar thickness can be identified, which enables the maximum flexion angle to be achieved. Using TC images, a healthy model was built. On this basis, a model of a knee joint which had undergone total knee arthroplasty using a Legion PS prosthesis was constructed. Initially, the standard thickness of patellar implant (9 mm) was used to build the model; then several different patellar implant thicknesses (in the range of 5-15 mm) were analyzed.

Results: The results show a non-linear trend: a button thickness of less than 9 mm does not change the flexion angle, whereas a button thickness of over 9 mm results in a loss of flexion. The flexion loss is significant in the first two additions of thicknesses but negligible in the last ones.

Conclusions: In the case studied, flexion reduction is not linearly proportional to the patellar thickness. The outcome of total knee arthroplasty is considered to be satisfactory with the standard patellar button. The results of this study could be used to compare the kinematics with other total prosthesis and patellar implants, and should enable the optimization of the patellar residue bone thickness to obtain deep flexion.

Download full-text PDF

Source

Publication Analysis

Top Keywords

total knee
16
knee arthroplasty
16
button thickness
12
knee flexion
12
patellar thickness
12
knee
10
flexion
9
patellar
9
influence patellar
8
patellar button
8

Similar Publications

Objectives: Home assessment and modification are crucial to prevent fall and fall-related injuries, especially in vulnerable subjects. This study assessed the need for home modifications and investigated risk factors associated with home injuries in post-total knee arthroplasty (TKA) patients.

Methods: This study was conducted at the university hospital from July 2022 to July 2023.

View Article and Find Full Text PDF

Functional alignment is a feasible alignment strategy in robotic assisted total knee arthroplasty for knee osteoarthritis with extra-articular deformity - A case series.

SICOT J

January 2025

Department of Orthopaedic Surgery, Joint Replacement Unit, Kuala Lumpur Hospital, Ministry of Health Malaysia, Jalan Pahang, 50586 Kuala Lumpur, Malaysia.

Introduction: Extraarticular deformity (EAD) with knee arthritis is a complex condition involving tri-planar bone deformity with pathological malalignment and chronic soft tissue contracture or laxity in the knee joint. Intraarticular correction by TKA, which was previously performed with conventional manual jig by mechanical alignment technique, had its limits and difficulties especially extensive soft tissue release and risk of jeopardizing the collateral ligaments. Robotic technology allows for reproducible and precise execution of surgical plan and allows adjustment to various new personalised alignment philosophy including functional alignment (FA).

View Article and Find Full Text PDF

Knee osteoarthritis (KOA) is a healthcare burden affecting over 595 million people worldwide. Recently, intra-articular platelet-rich plasma (PRP) injections from the patient's blood have shown promise in slowing KOA progression due to platelets' regenerative properties. This study aimed to evaluate the optimal dosing and schedule for PRP therapy in managing mild to moderate KOA.

View Article and Find Full Text PDF

Purpose: This study aimed to evaluate the effectiveness and safety of combination treatment with thread-embedding acupuncture (TEA) and electroacupuncture (EA) in patients with persistent knee pain after arthroscopic surgery, autologous chondrocyte implantation, or autologous osteochondral transplantation.

Patients And Methods: Twelve patients with knee osteoarthritis (KOA) who experienced postoperative pain were randomized to either the treatment group (TG) or control group (CG) in a 1:1 ratio. The TG received TEA once a week for four sessions and EA twice a week for eight sessions while continuing usual care, defined as standard conventional treatments.

View Article and Find Full Text PDF

Essential amino acid (EAA) supplementation, including conditionally essential amino acid (CEAA) and branched-chain amino acids (BCAA) supplementation, has been suggested as a mechanism to optimize patient outcomes by counteracting the atrophy associated with orthopedic procedures. We sought to investigate the effect of EAA supplementation in the perioperative period on patients undergoing orthopedic and spine surgery, specifically whether it is associated with (1) reductions in postoperative muscle atrophy and (2) improved postoperative function including range of motion, strength, and mobility. We conducted a systematic review of the literature.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!