In patients with enhanced risk for bleeding, heparin-free hemodialysis (HD) with conventional dialyzers is routinely used. To explore the potential benefit of using heparin-coated dialyzers, we used a reference CT-scanning technique and registered different clotting parameters to quantify coagulation with heparin-coated versus non-coated dialyzers. Six HD patients with thrombocytopenia were dialyzed 240 min in a randomized crossover study with Evodial 1.3 or FX600 Cordiax, each without anticoagulation. Blood samples were taken from the vascular access predialysis, and from the dialyzer inlet and outlet at 5 and 240 min after dialysis start. Predialysis blood samples were analyzed for hemoglobin, hematocrit, thrombocytes, fibrinogen, and activated partial thromboplastin time. On dialyzer inlet and outlet blood samples, a viscoelastic measurement of blood coagulation was performed using a Sonoclot analyzer. After dialysis, dialyzers were visually scored, subsequently dried for 24 h, weighed, and scanned with micro-CT at a resolution of 25 µm. After image reconstruction, the open, non-coagulated fibers were counted in a representative cross-section at the dialyzer outlet. No sessions were terminated prematurely for circuit clotting. Heparin-coated dialyzers had more patent fibers on micro-CT versus non-coated dialyzers and also had a better score of subjective visual assessment of fiber clotting. There was no difference in subjective assessment of clotting at the venous drip chamber. With both dialyzers, all ACT values remained in the normal range, and were lower at the dialyzer outlet versus inlet. In conclusion, dialysis with a heparin-coated versus non heparin-coated membrane results in substantially less coagulated fibers during 4 h hemodialysis without systemic anticoagulation. Eventual leaching of heparin, immobilized on the fiber membrane, does not result in measurable systemic anticoagulation.

Download full-text PDF

Source
http://dx.doi.org/10.1111/aor.13452DOI Listing

Publication Analysis

Top Keywords

blood samples
12
patients thrombocytopenia
8
randomized crossover
8
crossover study
8
heparin-coated dialyzers
8
heparin-coated versus
8
versus non-coated
8
non-coated dialyzers
8
dialyzer inlet
8
inlet outlet
8

Similar Publications

Clinical evidence increasingly suggests that traditional treatments for dysfunctional uterine bleeding (DUB) have limited success. In this study, blood samples from 10 DUB patients and 10 healthy controls were collected for transcriptome sequencing. Then, the differentially expressed genes (DEGs) were screened and crossed with the DUB-related module genes to obtain the target genes.

View Article and Find Full Text PDF

Fluctuations in circulating cell-free mitochondrial and nuclear DNA copy numbers in blood plasma after anti-tuberculosis drug intake in patients with drug-susceptible tuberculosis.

Tuberculosis (Edinb)

January 2025

Latvian Biomedical Research and Study Centre, Ratsupites street 1, k-1, Riga, LV-1067, Latvia; Riga Stradiņš University, Pharmacogenetic and Precision Medicine Laboratory, Konsula street 21, Riga, LV-1007, Latvia. Electronic address:

Biomarker research characterising the effect of anti-tuberculosis (TB) chemotherapy on systemic body response is still limited. In this study, we aimed to investigate fluctuations in circulating cell-free mitochondrial DNA (ccf-mtDNA) and circulating cell-free nuclear DNA (ccf-nDNA) copy number (CN) in blood plasma of patients with drug-susceptible TB (DS-TB) and to decipher factors related to these fluctuations. The results showed considerable changes in ccf-mtDNA CN in plasma samples before drug intake and 2 and 6 h afterwards, with high inter patient variability at each time point.

View Article and Find Full Text PDF

Electrochemical impedance spectroscopy has great potential for laboratory blood tests. The overall aim of this study is to develop a microfluidic sensor for determining the physical properties and hematological parameters of blood based on its dielectric spectra. Impedance was measured in flowing blood to prevent aggregation and sedimentation at frequencies between 40 Hz and 110 MHz.

View Article and Find Full Text PDF

Protocol for assessing and visualizing cell microaggregate formation in whole blood by imaging flow cytometry.

STAR Protoc

January 2025

Heinz-Nixdorf-Chair of Biomedical Electronics, TranslaTUM, School of Computation, Information and Technology, TUM, Germany; Munich Institute of Biomedical Engineering, TUM, Germany. Electronic address:

Blood cell aggregates are clinically useful biomarkers in a number of medical disorders. This protocol provides accurate and quantitative analysis of cell aggregates using a small volume of whole blood and imaging flow cytometry. We describe steps for sample collection, staining, and measurement.

View Article and Find Full Text PDF

Background: Neonatal sepsis (NNS) is a known cause of morbidity and mortality especially in developing countries. The global resistance scourge may worsen the management outcomes of NNS. This study aims to determine the current profile of bacteriological agents of NNS, their resistance status and associated mortality in our setting.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!