Acquired von Willebrand factor deficiency is reduced in HeartMate 3 patients†.

Eur J Cardiothorac Surg

Department of Cardiac Surgery, University of Leipzig, Heart Center Leipzig, Helios Clinic, Leipzig, Germany.

Published: September 2019

Objectives: The acquired von Willebrand syndrome (AvWS), which is associated with left ventricular assist device support, is caused by the loss of the von Willebrand factor (vWF) high molecular weight multimers (HMWMs). We investigated whether the implantation of the left ventricular assist device HeartMate 3 (HM 3) is superior to the HeartWare ventricular assist device (HVAD) in preserving the multimeric structure of vWF.

Methods: In total, 70 patients with implanted HM 3 (n = 35) or HVAD (n = 35) were retrospectively investigated. HMWMs, intermediate molecular weight multimers and low molecular weight multimers were quantified by using a densitometric methodology. vWF antigen, vWF activity and vWF collagen-binding activity, as well as demographic and clinical data, were analysed.

Results: AvWS, which is characterized by a decrease in vWF HMWMs, was found in 97.1% of patients in the HM 3 group and 100% of patients in the HVAD group. Compared to normal pooled plasma, HM 3 induced a reduction in HMWMs (40.7 ± 8.2% vs 26.7 ± 7.5%, P < 0.01) and an increase in low molecular weight multimers (31.3 ± 11.8% vs 42.7 ± 9.8%, P < 0.01), whereas HVAD patients exhibited an increase in the percentage of intermediate molecular weight multimers (28.0 ± 5.0% vs 38.4 ± 7.7%, P < 0.01) in addition to a decrease in the percentage of HMWM (23.0 ± 11.0%, P < 0.01). A comparison of both left ventricular assist device types showed a difference in vWF multimeric structure (HMWMs: P < 0.01, intermediate molecular weight multimer: P = 0.05, low molecular weight multimer: P = 0.03). Furthermore, vWF activity was elevated in patients with an implanted HM 3 device (153.7 ± 54.4%) compared to those with an HVAD device (126.3 ± 39.7%, P = 0.02).

Conclusions: Patients with an implanted HM 3 had more intact HMWMs and a higher vWF activity during device support. This may reduce the manifestation of AvWS in HM 3 patients and could thus lead to a lower bleeding complication rate.

Download full-text PDF

Source
http://dx.doi.org/10.1093/ejcts/ezz045DOI Listing

Publication Analysis

Top Keywords

von willebrand
12
ventricular assist
12
assist device
12
molecular weight
12
weight multimers
12
acquired von
8
willebrand factor
8
left ventricular
8
vwf
5
factor deficiency
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!