Low-Frequency Noise Investigation of 1.09 μm GaAsBi Laser Diodes.

Materials (Basel)

Institute of Applied Electrodynamics and Telecommunications, Vilnius University, Saulėtekio av. 3, LT-10257 Vilnius, Lithuania.

Published: February 2019

GaAsBi is a suitable and very attractive material system to be used as an active layer in laser diodes (LDs). To understand the performance and the reliability of such devices and also for further laser diode improvements, the origin of noise sources should be clarified. A detailed study of near-infrared 1.09 μm wavelength GaAsBi type-I laser diodes using the low-frequency noise spectroscopy in a temperature range of (180⁻300) K is presented. Different types of voltage fluctuation spectral density dependencies on the forward current far below the lasing threshold have been observed. According to this, investigated samples have been classified into two groups and two equivalent noise circuits with the corresponding voltage noise sources are presented. Calculations on the voltage spectral density of the electrical noise and current-voltage characteristic approximations have been performed and the results are consistent with the experimental data. The analysis showed that one group of LDs is characterized by 1/-type electrical fluctuations with one steep electrical bump in the electrical noise dependence on forward current, and the origin of these fluctuations is the surface leakage channel. The LDs of the other group have two bumps in the electrical noise dependence on current where the first bump is determined by overall LD defectiveness and the second bump by Bi-related defects in the active area of LD with characteristic Lorentzian-type fluctuations having the activation energy of (0.16⁻0.18) eV.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6416598PMC
http://dx.doi.org/10.3390/ma12040673DOI Listing

Publication Analysis

Top Keywords

laser diodes
12
electrical noise
12
low-frequency noise
8
109 μm
8
noise sources
8
spectral density
8
forward current
8
noise dependence
8
noise
7
electrical
5

Similar Publications

This study presents a novel optoporation technique using a titanium-coated TiO microstructure (TMS) device activated by an infrared diode laser for highly efficient intracellular delivery. The TMS device, fabricated with 120 nm titanium coating on a titanium dioxide (TiO) microstructure containing microneedles (height ∼2 μm and width ∼4.5 μm), demonstrates enhanced biocompatibility and thermal conductivity compared to the conventional TiO microstructure (MS).

View Article and Find Full Text PDF

The aim of this study was to compare the effectiveness of different types of low level laser treatment (LLLT) in reducing pain levels, changing oxygen saturation and bite force in patients with myofacial pain syndrome (MPS). 45 patients were randomly assigned to three groups: Group 1 (GRR laser, n = 15) received LLLT with Gallium-Aluminium-Arsenide (GaAlAs) diode laser with a wavelength of 904 nm and red laser with a wavelength of 650 nm over masseter muscle region. Group 2 (Nd: YAG laser, n = 15) were treated with Neodymium-doped Yttrium Aluminium Garnet laser with a wavelength of 1064 nm and the same protocol with Nd: YAG laser was performed in the Group 3 (placebo, n = 15) using sham device.

View Article and Find Full Text PDF

Significance: Cerebral blood flow (CBF) and cerebral blood volume (CBV) are key metrics for regional cerebrovascular monitoring. Simultaneous, non-invasive measurement of CBF and CBV at different brain locations would advance cerebrovascular monitoring and pave the way for brain injury detection as current brain injury diagnostic methods are often constrained by high costs, limited sensitivity, and reliance on subjective symptom reporting.

Aim: We aim to develop a multi-channel non-invasive optical system for measuring CBF and CBV at different regions of the brain simultaneously with a cost-effective, reliable, and scalable system capable of detecting potential differences in CBF and CBV across different regions of the brain.

View Article and Find Full Text PDF

This in-vitro study assessed the influence of the shade of human teeth on the transmission of near-infrared light. A total of 40 teeth were used. After cleaning the root surface and removing cementum, the teeth were sectioned into slices 3 mm thick, with each comprising a portion of the crown (enamel-dentine (ED)) and of the root (dentine only).

View Article and Find Full Text PDF

Oral candidiasis, predominantly caused by , presents significant challenges in treatment due to increasing antifungal resistance and biofilm formation. Antimicrobial photodynamic therapy (aPDT) using natural photosensitizers like riboflavin and hypericin offers a potential alternative to conventional antifungal therapies. : A systematic review was conducted to evaluate the efficacy of riboflavin- and hypericin-mediated aPDT in reducing Candida infections.

View Article and Find Full Text PDF