Computed tomography (CT) is currently the reference modality for the detection and follow-up of pulmonary nodules. While 2D measurements are commonly used in clinical practice to assess growth, increasingly 3D volume measurements are being recommended. The goal of this pilot study was to evaluate preliminarily the capabilities of 3D MRI using ultra-short echo time for lung nodule volumetry, as it would provide a radiation-free modality for this task. Artificial nodules were manufactured out of Agar and measured using an ultra-short echo time MRI sequence. CT data were also acquired as a reference. Image segmentation was carried out using an algorithm based on signal intensity thresholding (SIT). For comparison purposes, we also performed manual slice by slice segmentation. Volumes obtained with MRI and CT were compared. Finally, the volumetry of a lung nodule was evaluated in one human subject in comparison with CT. Using the SIT technique, minimal bias was observed between CT and MRI across the entire range of volumes (2%) with limits of agreement below 14%. Comparison of manually segmented MRI and CT resulted in a larger bias (8%) and wider limits of agreement (-23% to 40%). , nodule volume differed of <16% between modalities with the SIT technique. This pilot study showed very good concordance between CT and UTE-MRI to quantify lung nodule volumes, in both a phantom and human setting. Our results enhance the potential of MRI to quantify pulmonary nodule volume with similar performance to CT.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6379285PMC
http://dx.doi.org/10.3389/fmed.2019.00018DOI Listing

Publication Analysis

Top Keywords

volumetry lung
8
pilot study
8
ultra-short echo
8
echo time
8
lung nodule
8
limits agreement
8
mri
5
lung nodules
4
nodules pilot
4
study computed
4

Similar Publications

Purpose: To assess agreement between CT volumetry change classifications derived from Quantitative Imaging Biomarker Alliance Profile cut-points (ie, QIBA CTvol classifications) and the Response Evaluation Criteria in Solid Tumors (RECIST) categories.

Materials And Methods: Target lesions in lung, liver, and lymph nodes were randomly chosen from patients in 10 historical clinical trials for various cancers, ensuring a balanced representation of lesion types, diameter ranges described in the QIBA Profile, and variations in change magnitudes. Three radiologists independently segmented these lesions at baseline and follow-up scans using 2 software tools.

View Article and Find Full Text PDF

Improved Consistency of Lung Nodule Categorization in CT Scans with Heterogeneous Slice Thickness by Deep Learning-Based 3D Super-Resolution.

Diagnostics (Basel)

December 2024

Department of Applied Bioengineering, Graduate School of Convergence Science and Technology, Seoul National University, Seoul 08826, Republic of Korea.

: Accurate volumetric assessment of lung nodules is an essential element of low-dose lung cancer screening programs. Current guidance recommends applying specific thresholds to measured nodule volume to make the following clinical decisions. In reality, however, CT scans often have heterogeneous slice thickness which is known to adversely impact the accuracy of nodule volume assessment.

View Article and Find Full Text PDF

Background: Computed tomography pulmonary angiography (CTPA) is frequently performed in patients with pulmonary hypertension (PH) and may aid non-invasive estimation of pulmonary hemodynamics. We, therefore, investigated automated volumetry of intrapulmonary vasculature on CTPA, separated into core and peel fractions of the lung volume and its potential to differentially reflect pulmonary hemodynamics in patients with pre- and postcapillary PH.

Methods: A retrospective case-control study of 72 consecutive patients with PH according to the 2022 joint guidelines of the European Society of Cardiology and the European Respiratory Society who underwent right heart catheterization (RHC) and CTPA within 7 days between August 2013 and February 2016 at Thoraxklinik at Heidelberg University Hospital (Heidelberg, Germany) was conducted.

View Article and Find Full Text PDF

Effect of residual lung expansion on pulmonary function after lobectomy.

Gen Thorac Cardiovasc Surg

January 2025

Department of Thoracic Surgery, Jikei University School of Medicine, 3-19-18, Nishishimbashi, Minato-ku, Tokyo, 105-8471, Japan.

Objectives: Pulmonary function after lobectomy is often higher than what is predicted. This occurrence could be related to postoperative expansion of the residual lung. The study aim was to determine if residual lung expansion affects pulmonary function after lobectomy.

View Article and Find Full Text PDF
Article Synopsis
  • AI-CAC automated left atrial volumetry offers more actionable insights compared to traditional methods like the Agatston coronary artery calcium score, predicting atrial fibrillation (AF) as early as one year.
  • The study evaluated the effectiveness of AI-CAC against human-measured left atrial volumes using cardiac magnetic resonance imaging (CMRI) in predicting AF and stroke, alongside established risk scores and biomarkers.
  • Results showed that AI-CAC and CMRI provided similar predictive capabilities for AF and stroke over a 15-year period, indicating potential for AI-CAC in clinical settings, but further research is needed to confirm its utility.