Objective: The impact of vaginal instrumentation on operative time for robotic-assisted sacrocolpopexy (RSC) is not well understood. Colpassist (Boston Scientific, Quincy, Mass) is a vaginal positioning device designed to improve exposure with a curved double-sided handle that can be adapted to patient anatomy with 2 different sized functional ends. We sought to compare operative time for RSC using a Colpassist compared with a traditional end-to-end anastomosis sizer (EEAS).

Methods: This was a single-center randomized controlled trial of consecutive women undergoing RSC for apical pelvic organ prolapse. Participants were randomized to undergo RSC using either Colpassist or EEAS. The primary outcome was total operative time for the steps of RSC requiring use of a vaginal positioning device. Secondary outcomes included injury rates and satisfaction of the participants.

Results: Fifty-two women were enrolled (25 Colpassist, 27 EEAS). For the primary outcome, there was no significant difference in total operative time between procedures performed with Colpassist versus EEAS (P = 0.15). However, 16 (64%) of the 25 Colpassist arm versus 0 of EEAS (P < 0.01) required use of an alternative vaginal positioning device intraoperatively. Comparing secondary outcomes, there were no differences in rate of intraoperative injury between groups. Surgeon and fellow satisfaction scores were lower with Colpassist (P < 0.01). Surgical vaginal assistants were equally satisfied with both vaginal positioning devices (P > 0.05).

Conclusions: Colpassist is a potential alternative to EEAS with no significant difference in operative time or complication rate. However, case completion with Colpassist was significantly lower than EEAS and was associated with lower surgeon and fellow satisfaction.

Download full-text PDF

Source
http://dx.doi.org/10.1097/SPV.0000000000000692DOI Listing

Publication Analysis

Top Keywords

operative time
20
vaginal positioning
16
positioning device
12
colpassist
10
colpassist versus
8
end-to-end anastomosis
8
anastomosis sizer
8
robotic-assisted sacrocolpopexy
8
randomized controlled
8
controlled trial
8

Similar Publications

Aims: Which is the best extensile lateral (ELA) or sinus tarsi (STA) approach for osteosynthesis displaced intraarticular calcaneal fracture (DIACF) is still debatable. The current RCT's primary objective was to compare the complications incidence after open reduction and internal fixation of DIACFs through STA vs. ELA.

View Article and Find Full Text PDF

Flow-Based Coronary Artery Bypass Graft Patency Metrics: Uncertainty Quantification Simulations to Guide Development.

Cardiovasc Eng Technol

January 2025

Transonic Systems Inc., 34 Dutch Mill Road, Ithaca, New York, 14850, USA.

Purpose: Over time, transit time flow measurement (TTFM) has proven itself as a simple and effective tool for intra-operative evaluation of coronary artery bypass grafts (CABGs). However, metrics used to screen for possible technical error show considerable spread, preventing the definition of sharp cut-off values to distinguish between patent, questionable, and failed grafts. The simulation study presented in this paper aims to quantify this uncertainty for commonly used patency metrics, and to identify the most important physiological parameters influencing it.

View Article and Find Full Text PDF

A randomized cohort study on the use of 3D printed models to enhance surgical training in suturing techniques.

Sci Rep

January 2025

General Surgery, Cancer Center, Department of Hernia Surgery, Zhejiang Provincial People's Hospital (Affiliated People's Hospital), Hangzhou Medical College, Hangzhou, 310014, China.

Three-dimensional (3D) printed surgical models provide an excellent surgical training option to closely mimic real operations to teach medical students who currently rely largely on visual learning aided with simple suturing pads. There is an unmet need to create simple to complex surgical training programs suitable for medical students. A prospective cohort study was conducted on a group of 16 6th year students.

View Article and Find Full Text PDF

Backgroud: Medial humeral epicondyle fracture is a prevalent type of upper limb fractures in pediatric patients. This study aims to compare the follow-up clinical results and complications in 30 children with medial epicondyle fractures who were treated with either metal screws or absorbable screws at our hospital.

Methods: A retrospective review was conducted on 30 children with medial humeral epicondyle fractures, who were divided into two groups: Metal group (18 children) underwent fixation using metal screws, while Absorbable group (12 children) received absorbable screws between January 2016 and June 2024.

View Article and Find Full Text PDF

Objective: To evaluate the added value of dynamic contrast-enhanced ultrasound (DCE-US) analysis in pre-operative differential diagnosis of small (≤20 mm) solid pancreatic lesions (SPLs).

Methods: In this retrospective study, patients with biopsy or surgerical resection and histopathologically confirmed small (≤20 mm) SPLs were included. One wk before biopsy/surgery, pre-operative B-mode ultrasound and contrast-enhanced ultrasound were performed.

View Article and Find Full Text PDF