Comparative evaluation of SPECT/CT and CBCT in patients with mandibular osteomyelitis and osteonecrosis.

Clin Oral Investig

Department of Cranio-Maxillofacial Surgery, Inselspital, Bern University Hospital, University of Bern, Freiburgstrasse, 3010, Bern, Switzerland.

Published: December 2019

Objectives: Therapy of osteomyelitis and osteonecrosis very often requires surgery. Proper preoperative radiological evaluation of a lesion's localization and extent is a key in planning surgical bone resection. This study aims to assess the differences between single-photon emission computed tomography and cone beam computed tomography when detecting an osteomyelitis/osteonecrosis lesion as well as the lesion's qualitative parameters, extent, and localization.

Material And Methods: Identification of candidates was performed retrospectively following a search for patients with histologically or clinically confirmed osteomyelitis or osteonecrosis. They were matched with a list of patients whose disease extent and localization had been evaluated using single-photon emission computed tomography and cone beam computed tomography in the context of clinical investigations. Subsequently, two experienced examiners for each imaging technique separately performed de novo readings. Detection rate, localization, extent, and qualitative parameters of a lesion were then compared.

Results: Twenty-one patients with mandibular osteomyelitis and osteonecrotic lesions were included. Cone beam computed tomography detected more lesions than single-photon emission computed tomography (25 vs. 23; 100% vs. 92%). Cone beam computed tomography showed significantly greater depth, area, and volume, whereas length and width did not differ statistically between the two groups.

Conclusion: Both single-photon emission computed tomography and cone beam computed tomography could sensitively detect osteomyelitis/osteonecrosis lesions. Only single-photon emission computed tomography showed metabolic changes, whereas cone beam computed tomography seemed to display anatomic morphological reactions more accurately. The selection of the most adequate three-dimensional imaging and the correct interpretation of preoperative imaging remains challenging for clinicians.

Clinical Relevance: In daily clinical practice, three-dimensional imaging is an important tool for evaluation of osteomyelitis/osteonecrosis lesions. In this context, clinicians should be aware of differences between single-photon emission computed tomography and cone beam computed tomography when detecting and assessing an osteomyelitis/osteonecrosis lesion, especially if a surgical bone resection is planned.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00784-019-02862-8DOI Listing

Publication Analysis

Top Keywords

computed tomography
52
cone beam
28
beam computed
28
single-photon emission
24
emission computed
24
tomography cone
16
computed
13
tomography
13
osteomyelitis osteonecrosis
12
patients mandibular
8

Similar Publications

Background: Kidney tumors, common in the urinary system, have widely varying survival rates post-surgery. Current prognostic methods rely on invasive biopsies, highlighting the need for non-invasive, accurate prediction models to assist in clinical decision-making.

Purpose: This study aimed to construct a K-means clustering algorithm enhanced by Transformer-based feature transformation to predict the overall survival rate of patients after kidney tumor resection and provide an interpretability analysis of the model to assist in clinical decision-making.

View Article and Find Full Text PDF

Objectives: This study evaluates the potential of pulp volume/total tooth-volume measurements of canine teeth in relation to chronologic age in patients with cleft lip and palate (CLP). The significance of this study lies in its exploration of the usability of these measurements for age determination in CLP patients, providing a novel perspective to the existing literature.

Methods: Cone beam computed tomography images of 33 patients (16 females, 17 males) with unilateral CLP aged 14-45 years and 33 age- and sex-matched healthy individuals (16 females, 17 males) were retrospectively evaluated.

View Article and Find Full Text PDF

Rib pathology is uniquely difficult and time-consuming for radiologists to diagnose. AI can reduce radiologist workload and serve as a tool to improve accurate diagnosis. To date, no reviews have been performed synthesizing identification of rib fracture data on AI and its diagnostic performance on X-ray and CT scans of rib fractures and its comparison to physicians.

View Article and Find Full Text PDF

Rising computed tomography (CT) workloads require more efficient image interpretation methods. Digitally reconstructed radiographs (DRRs), generated from CT data, may enhance workflow efficiency by enabling faster radiological assessments. Various techniques exist for generating DRRs.

View Article and Find Full Text PDF

The use of conventional contrast agents in computed tomography (CT) and magnetic resonance (MR) imaging is often limited in patients with chronic kidney disease (CKD) due to potential nephrotoxicity. Ferumoxytol, originally developed for iron supplementation, has emerged as a promising alternative MR contrast agent that is safer for patients with CKD. This study aims to present our center's experience with ferumoxytol as a contrast agent in CKD patients.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!