Background: Methods for detecting the complex genetic characteristics of α- and β-thalassemias are required for preventing and controlling the outbreak of new cases.

Methods: We evaluated the accuracy and practical utility of microarray for simultaneous detection of α- and β-thalassemias. A total of 102 DNA specimens, which represented 25 different genotypes, were tested in parallel using the microarray and reference methods used in the thalassemia laboratory of the Associated Medical Sciences-Clinical Services Center (AMS-CSC), Chiang Mai, Thailand.

Results: A total of 100 (98.0%) DNA specimens were completely concordant between the microarray and reference methods, whereas discrepancies between the different methods were observed in only 2 DNA specimens with homozygous hemoglobin E (HbE).

Conclusions: The microarray appeared to be a fast, easy to perform, and accurate method for simultaneous detection of α- and β-thalassemias in Thailand and Southeast Asian countries. However, this technique needs to be improved and validated in a larger number of specimens with homozygous HbE before further routine laboratory use.

Download full-text PDF

Source
http://dx.doi.org/10.1093/labmed/lmy087DOI Listing

Publication Analysis

Top Keywords

simultaneous detection
12
α- β-thalassemias
12
dna specimens
12
microarray simultaneous
8
detection α-
8
microarray reference
8
reference methods
8
specimens homozygous
8
validation microarray
4
detection common
4

Similar Publications

Purpose: With the widespread introduction of dual energy computed tomography (DECT), applications utilizing the spectral information to perform material decomposition became available. Among these, a popular application is to decompose contrast-enhanced CT images into virtual non-contrast (VNC) or virtual non-iodine images and into iodine maps. In 2021, photon-counting CT (PCCT) was introduced, which is another spectral CT modality.

View Article and Find Full Text PDF

A compact dual-gas sensor based on the two near-infrared distributed feedback diode lasers and a multipass cell has been established for the simultaneous measurement of methane (CH) and acetylene (CH). The time division multiplexing calibration-free direct absorption spectroscopy is used to eliminate the cross interference in the application of multicomponent gas sensors. A wavelength stabilization technique based on the proportion integration differentiation feedback control is developed to suppress laser wavelength drift and an H-infinity (H) filter algorithm to reduce the system noise.

View Article and Find Full Text PDF

In this study, a Cu@Ag core-shell was synthesized using a co-precipitation method. To create a new electrochemical sensor, a Cu@Ag core-shell with conductive polymers such as polyalizarin yellow R (PA) and Nafion (Nf) was immobilized on the surface of a glassy carbon electrode (Cu@Ag-Nf/PA/GCE). X-ray diffraction analysis (XRD), energy dispersive X-ray analysis (EDX), transmission electron microscopy (TEM), and Fourier Transform Infrared Spectroscopy (FTIR) techniques were employed to characterize the Cu@Ag-Nf/PA/GCE.

View Article and Find Full Text PDF

Kounis Syndrome Following Moxifloxacin and Deflazacort Administration.

Eur J Case Rep Intern Med

December 2024

Emergency Department, Ente Ospedaliero Cantonale - Ospedale Regionale di Lugano, Lugano, Switzerland.

Unlabelled: Kounis syndrome (KS), characterized by the simultaneous occurrence of acute coronary syndrome (ACS) and allergic reactions, can be triggered by a range of factors and drugs. We report on the case of a patient who arrived at our emergency department (ED) with symptoms of an allergic reaction after taking moxifloxacin and deflazacort orally. In the ED, the patient experienced a 5-minute episode of oppressive chest pain.

View Article and Find Full Text PDF

The development of multitargeted drugs is urgent for ischemic stroke. TRPV1 and TRPM8 are important targets of ischemic stroke. Previous drug candidate screening has identified that muscone, l-borneol, and ferulic acid may target TRPV1 and TRPM8 for ischemic stroke.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!