Lower limb external maximal power output capacity is a key physical component of performance in many sports. During squat jump and countermovement jump tests, athletes produce high amounts of mechanical work over a short duration to displace their body mass (i.e. the dimension of mechanical power). Thus, jump height has been frequently used by the sports science and medicine communities as an indicator of the power output produced during the jump and by extension, of maximal power output capacity. However, in this article, we contend that squat jump and countermovement jump height are not systematically good indicators of power output produced during the jump and maximal power output capacity. To support our opinion, we first detail why, theoretically, jump height and maximal power output capacity are not fully related. Specifically, we demonstrate that individual body mass, push-off distance, optimal loading and the force-velocity profile confound the jump height-power relationship. We also discuss the relationship between squat jump or countermovement jump height and maximal power output capacity measured with a force plate based on data reported in the literature, which added to our own experimental evidence. Finally, we discuss the limitations of existing practical solutions (regression-based estimation equations and allometric scaling), and advocate using a valid, reliable and simple field-based procedure to compute individual power output produced during the jump and maximal power output capacity directly from jump height, body mass and push-off distance. The latter may allow researchers and practitioners to reduce bias in their assessment of lower limb mechanical power output by using jump height as an input with a simple yet accurate computation method, and not as the first/only variable of interest.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s40279-019-01073-1 | DOI Listing |
Sci Rep
January 2025
School of ECE, Adama Science and Technology University, Adama, Ethiopia.
This paper details the hardware implementation of a Universal Converter controlled by an Artificial Neural Network (ANN), utilizing key components such as six Insulated Gate Bipolar Transistors (IGBTs), two inductors, and two capacitors for energy storage and voltage smoothing. A Digital Signal Processor (DSP) serves as the core controller, processing real-time input and feedback signals, including voltage and current measurements, to dynamically manage five operational modes: rectifier buck, inverter boost, DC-DC buck, DC-DC boost, and AC voltage control. The pre-trained ANN algorithm generates pulse-width modulation (PWM) signals to control the switching of the IGBTs, optimizing timing and duty cycles for efficient operation.
View Article and Find Full Text PDFJ Hazard Mater
January 2025
Engineering Research Center of Groundwater Pollution Control and Remediation (Ministry of Education), College of Water Sciences, Beijing Normal University, No 19, Xinjiekouwai Street, Beijing 100875, China. Electronic address:
Electronic mediators are an effective means of enhancing the efficiency of microbial electrochemical electron transfer; however, there are still gaps in understanding the strengthening mechanisms and the efficiency of removing antibiotic resistance genes (ARGs) and antibiotic-resistant bacteria (ARB). This study systematically elucidates the effects of various electron mediators on bioelectrochemical processes, electron transfer efficiency, and the underlying mechanisms that inhibit ARG propagation within sediment microbial fuel cell systems (SMFCs). The results indicate that the addition of electron mediators significantly increased the output voltage (33.
View Article and Find Full Text PDFACS Nano
January 2025
School of Mechanical Engineering, Sichuan University, Chengdu 610065, China.
Natural skin receptors use ions as signal carriers, while most of the developed artificial tactile sensors utilize electrons as information carriers. To imitate the biological ionic sensing behavior, here, we present a kind of biomimetic, ionic, and fully passive mechanotransduction mechanism leveraging mechanical modulation of interfacial ionic p-n junction (IPNJ) through microchannels. Sensors based on this mechanism do not rely on an external power supply and can encode external tactile stimuli into highly analogous signal outputs to those of natural skin receptors, in terms of both signal type (i.
View Article and Find Full Text PDFJ Chem Inf Model
January 2025
Center for Engineering Concepts Development, Department of Mechanical Engineering, University of Maryland, College Park, Maryland 20742, United States.
In 2020, nearly 3 million scientific and engineering papers were published worldwide (White, K. Publications Output: U.S.
View Article and Find Full Text PDFRev Sci Instrum
January 2025
Key Laboratory of Advanced Science and Technology on High Power Microwave, Northwest Institute of Nuclear Technology, Xi'an 710024, China.
The testing and modeling of semiconductor devices are the foundation of circuit design. The issue of high-power device testing urgently needs to be solved as the power level of the devices under test (DUTs) increases. This work proposes advanced measurement methods based on three aspects of "measuring capability, security, and stability" with a focus on the features of high output power, easy self-oscillation in mismatch tests, and safety risk in the measurement system of high-power transistors.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!