A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The impact of upper-limb position on estimated central blood pressure waveforms. | LitMetric

Pulse wave analysis (PWA) utilizes arm blood pressure (BP) waveforms to estimate aortic waveforms. The accuracy of central BP waveform estimation may be influenced by assessment site local haemodynamics. This study investigated whether local haemodynamic changes, induced via arm tilting ±30° relative to heart level, affect estimated central systolic BP (cSBP) and arterial wave reflection (central augmentation index, cAIx; aortic backward pressure wave, Pb). In 20 healthy adults (26.7 years [SD 5.2], 10 F) brachial BP waveforms were simultaneously recorded on experimental and control arms. The experimental arm was randomly repositioned three times (heart level, -30° heart level, +30° heart level), while the control arm remained fixed at heart level. For the experimental arm, arm repositioning resulted in a large (partial eta-squared > 0.14) effect size (ES) change in SBP (ES = 0.75, P < 0.001), cSBP (ES = 0.81, P < 0.001), and cAIx (ES = 0.75, P = 0.002), but not Pb (ES = 0.06, P = 0.38). In the control arm, cAIx (ES = 0.22, P = 0.013) but not SBP or cSBP significantly changed. Change in experimental arm cSBP was partially explained by brachial systolic blood velocity (P = 0.026) and mean diameter (P = 0.012), while change in cAIx was associated with brachial retrograde blood velocity (P = 0.020) and beta stiffness (P = 0.038). In conclusion, manipulation of assessment site local haemodynamics, including the blood velocity profile and local arterial stiffness, had a large effect on estimated cSBP and cAIx, but not on Pb. These findings do not invalidate PWA devices but do suggest that the accuracy of the estimated aortic pressure waveform is dependent on stable peripheral haemodynamics.

Download full-text PDF

Source
http://dx.doi.org/10.1038/s41371-019-0179-xDOI Listing

Publication Analysis

Top Keywords

heart level
20
estimated central
8
blood pressure
8
pressure waveforms
8
experimental arm
8
arm
6
heart
5
level
5
impact upper-limb
4
upper-limb position
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!