Background: The effects of edge-to-edge percutaneous mitral valve repair on the shape and size of the mitral annulus and its relation to mitral regurgitation (MR) have not been well characterized. We evaluated acute changes in mitral annular shape and dimensions, and their effect on MR severity, in patients with functional and degenerative MR following MitraClip .

Methods: Patients that underwent MitraClip between January 2013 and May 2016 at our institution were retrospectively reviewed.

Exclusions: inadequate images, prior mitral valve repair, and rapid atrial fibrillation. Intra-procedure TEE 3D images acquired prior to and after implantation of MitraClip were analyzed using software to model the mitral valve apparatus.

Results: Of seventy-eight patients that underwent MitraClip procedure, 60 were eligible. Mean age was 78.3 ± 11 years. Severe MR (4+) was present in 37 patients, moderately/severe MR (3+) in 23. All patients achieved MR reduction to ≤2. 3D annular circumference, bicommissural diameter, and anteroposterior diameter had a significant size reduction after MitraClip . None of the mitral annular measures had significantly different mean change between the large and small MR change groups at the 0.05 significance level.

Conclusions: In patients with functional or degenerative MR, the MitraClip significantly affect mitral annular dimensions; however, these changes do not correlate with the immediate MR reduction.

Download full-text PDF

Source
http://dx.doi.org/10.1111/echo.14284DOI Listing

Publication Analysis

Top Keywords

mitral valve
16
valve repair
12
mitral annular
12
mitral
11
effects edge-to-edge
8
edge-to-edge percutaneous
8
percutaneous mitral
8
repair shape
8
shape size
8
size mitral
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!