Purpose: To analyse the correlation between the fold change in residual liver volume (RLV) and residual liver uptake at 15 (RLU15) before and after percutaneous transhepatic portal vein embolisation (PTPE).
Material And Methods: Between August 2010 and December 2016, 20 patients who underwent PTPE were retrospectively selected. Before and three weeks after PTPE, contrast-enhanced computed tomography (CECT) and Tc-99m GSA scintigraphy were performed to analyse the fold changes in RLV and RLU15, respectively, as well as their correlation.
Results: After PTPE, a significant increase was observed in the RLV (before: 464 ± 99 ml; after: 573 ± 118 ml, = 0.004) and the RLU15 (before: 11.0 ± 2.9%; after: 17.7 ± 3.8%, = 5 × 10). The fold increase of RLV and RLU15 in all patients was 1.25 ± 0.15 and 1.66 ± 0.33, respectively. No significant correlation was observed in the fold increase in both RLV and RLU15 ( = 0.14, = 0.66). In patients no. 3 and 9, who were outliers, the increase in RLV was minimal and RLU15 increased greatly, and these 2 patients underwent radical hepatectomy after PTPE.
Conclusions: No correlation was observed between the fold increase in RLV and RLU15 before and after PTPE. In order to accurately evaluate the residual liver function, it should be considered necessary to evaluate not only by morphological CECT volumetry, but also by functional outcome of Tc-99m GSA scintigraphy.Residual liver volume may not necessarily reflect RLF. It may be possible to improve the radical resection rate by detecting the potential increase of RLF with RLU15 of Tc-99m GSA scintigraphy.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6384407 | PMC |
http://dx.doi.org/10.5114/pjr.2018.81155 | DOI Listing |
BMC Surg
November 2024
Department of Surgery, Fujita Health University, 1-98 Dengakugakubo, Kutsukake, Toyoake, Aichi, 470-1192, Japan.
Mol Imaging Biol
December 2024
Department of Radiology, Mie University Hospital, 2-174 Edobashi, Tsu, 514-8507, Mie, Japan.
Purpose: To evaluate the value of Tc-99m-diethylenetriamine-penta-acetic acid-galactosyl human serum albumin (Tc-GSA) single photon emission computed tomography (SPECT) for assessing liver fibrosis, and to assess its complementary value to other liver function indices such as fibrosis-4 (FIB-4) index and indocyanine green (ICG) clearance test parameters (ICG-R15 and ICG-K).
Procedures: Seventy-eight patients with chronic liver disease and hepatocellular carcinoma who underwent Tc-GSA scintigraphy and other liver function tests including ICG test and FIB-4 index prior to hepatectomy were studied. Tc-GSA imaging was performed with SPECT/CT scanner (Discovery NM/CT 670).
Jpn J Radiol
November 2024
Department of Radiology, Shinshu University School of Medicine, 3-1-1 Asahi, Matsumoto, Nagano, 390-8621, Japan.
Purpose: To evaluate the predictive ability of combining Technetium-99m-galactosyl human serum albumin (Tc‑GSA) single-photon emission computed tomography (SPECT)/computed tomography (CT) volume and plasma clearance rate of indocyanine green (ICGK) for posthepatectomy liver failure (PHLF).
Materials And Methods: Fifty patients who underwent Tc-GSA scintigraphy as a preoperative examination for segmentectomy or more from July 2021 to June 2023 were evaluated prospectively. Patients were divided into two groups according to the presence or absence of posthepatectomy liver failure (PHLF).
Radiol Phys Technol
March 2024
Department of Radiological Technology, Faculty of Health Sciences, Okayama University, 2-5-1 Shikata-Cho, Kita-Ku, Okayama-shi, Okayama, 700-8558, Japan.
This study aimed to evaluate a deep learning-based attenuation correction (AC) method to generate pseudo-computed tomography (CT) images from non-AC single-photon emission computed tomography images (SPECT) for AC in Tc-galactosyl human albumin diethylenetriamine pentaacetic acid (GSA) scintigraphy and to reduce patient dosage. A cycle-consistent generative network (CycleGAN) model was used to generate pseudo-CT images. The training datasets comprised approximately 850 liver phantom images obtained from SPECT and real CT images.
View Article and Find Full Text PDFCureus
July 2023
Department of Surgery, Meiwa Hospital, Hyogo, JPN.
Background The 99mTc-galactosyl human serum albumin (Tc-99m GSA) scintigraphy evaluates the future remnant liver function, which is an important prognostic factor for post-hepatectomy liver failure (PHLF). This study aimed to establish a new prognostic score for PHLF, including the functional liver parameters evaluated by Tc-99m GSA scintigraphy. Materials and methods This study reviewed a single-center, retrospective 368-patient database of those who underwent open and laparoscopic hepatectomy in Meiwa Hospital from January 2016 to October 2021.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!