A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Assessment on applicability of common source tracking tools for particulate organic matter in controlled end member mixing experiments. | LitMetric

Assessment on applicability of common source tracking tools for particulate organic matter in controlled end member mixing experiments.

Sci Total Environ

Department of Environment and Energy, Sejong University, Seoul 143-747, South Korea. Electronic address:

Published: May 2019

In this study, ideal mixing behaviors of the three commonly-used source tracking tools, which include fluorescence spectroscopy, stable isotope ratios, and lipid biomarkers, were evaluated in controlled particular organic matter (POM) mixtures of two contrasting end members e.g., soil and algae. In parallel, three different extraction methods based on water (WEOM) and two alkaline solutions were compared to identify the preferential pre-treatment option that leads to a good performance of the spectroscopic source tracking indices on the dissolved organic matter (DOM) extracted from the POM. Based on three evaluation criteria concerning the linearity of the relationships, the discrimination sensitivity, and the conservative mixing behavior of fourteen tested indices, the fluorescence proxies such as the relative distribution of the fluorescence components and the modified fluorescence index YFI of the WEOM were found to be reliable and robust indices for POM source tracking. The carbon stable isotope ratios of the POM samples exhibited an ideal mixing behavior even after the DOM extraction, while the biomarkers of sterols/stanols did not present a good linear and conservative behavior at similar conditions. In addition, the WEOM was identified as the preferred extraction method for the application of spectroscopic indices for POM source discrimination. This study provides a guideline to select the optimum indices for the POM source discrimination via the end member mixing analysis.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.scitotenv.2019.02.258DOI Listing

Publication Analysis

Top Keywords

source tracking
16
organic matter
12
indices pom
12
pom source
12
tracking tools
8
member mixing
8
ideal mixing
8
stable isotope
8
isotope ratios
8
mixing behavior
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!