Accuracy of crowns based on digital intraoral scanning compared to conventional impression-a split-mouth randomised clinical study.

Clin Oral Investig

Department of Dentistry and Oral Health, Aarhus University, Vennelyst Boulevard 9, DK-8000, Aarhus C, Denmark.

Published: November 2019

Objectives: The aim of this prospective in vivo study was to evaluate the accuracy of the marginal and internal fit of crowns based on conventional impression (CI) or intraoral scan (IOS) in a randomised, split-mouth set-up.

Materials And Methods: Nineteen patients needing full coverage crowns, fitting a split-mouth design, were provided with two lithium disilicate crowns: one based on a CI and one based on an IOS. The marginal and internal accuracy of the crowns were assessed with the replica technique and clinically using a modified California Dental Association (CDA) quality evaluation system.

Results: At the preparation margin, the median gap was 60 μm for IOS and 78 μm for CI. For the other points, the median gap ranged from 91 to 159 μm for IOS and 109 to 181 μm for CI. The accuracy of the IOS was statistically significantly better at all point except at the cusp tip. All crowns where rated R or S at both the 6- and 12-month follow-up appointments. The results for the clinical evaluation with CDA for marginal integrity showed no statistically significant difference between the two impression methods at both the 6- and 12-month evaluations.

Conclusions: Crowns based on IOS show statistically significantly better marginal and internal adaptation before cementation compared to conventional impression. However, the clinical evaluation showed similar marginal adaptation.

Clinical Relevance: Crowns based on a fully digital workflow can provide clinically acceptable marginal adaptation, comparable to crowns based on CI.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00784-019-02840-0DOI Listing

Publication Analysis

Top Keywords

crowns based
24
marginal internal
12
accuracy crowns
8
compared conventional
8
crowns
8
conventional impression
8
based ios
8
median gap
8
ios statistically
8
statistically better
8

Similar Publications

Rapid detection of sludge moisture content based on the frequency domain reflection.

Environ Technol

December 2024

College of Mechanical and Electrical Engineering, China Jiliang University, Hangzhou, People's Republic of China.

The moisture content (MC) of sludge is a critical factor affecting sludge treatment and disposal technologies. Traditional drying methods for measuring sludge MC are time-consuming and lack of portability. To achieve rapid online detection of sludge MC, this paper proposes a method based on frequency domain reflectometry.

View Article and Find Full Text PDF

Purpose: Baseline surveys were conducted in Tigray region, Ethiopia, in 2013. Since then, rounds of azithromycin mass drug administration (MDA) have been delivered in-line with international guidance. The purpose of these surveys was to assess trachomatous inflammation-follicular (TF) prevalence following those treatments to enable the region to plan the next steps towards elimination of trachoma.

View Article and Find Full Text PDF

Filling post-extraction alveoli with hydroxyapatite-based materials is becoming an increasingly common procedure in veterinary dentistry. In dogs, tooth roots vary in structure depending on the weight of the dog, but data on tooth length and volume have not yet been described. This study aimed to establish reference data on tooth root length and post-extraction alveolar volume for mature maxillary and mandibular incisors and canines in dogs.

View Article and Find Full Text PDF

: The rapid development of refrigerated transportation technology for fresh vegetables has extended their shelf life. Some vegetables may appear undamaged on the surface, but their freshness may have decreased, often resulting in the phenomenon of passing off inferior vegetables as good. It is very important to establish a detection method for identifying and assessing the freshness of vegetables.

View Article and Find Full Text PDF

The aim of the study is to assess the impact of mechanical surface treatments on the shear bond strength (SBS) of orthodontic brackets bonded to three-dimensional (3D) printed and milled CAD/CAM provisional materials. Sixty cylindrical samples were fabricated for each provisional material. Samples were treated with one of the following surface treatments: aluminum oxide airborne particle abrasion, diamond bur rotary instrument roughening, and phosphoric acid etching (control).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!