Purpose: Clinically evaluate intraocular pressure (IOP) measurements taken with a Goldmann applanation tonometer (GAT) prism and a modified surface Goldmann prism examining measurement differences correlated to central corneal thickness (CCT) and corneal hysteresis (CH) values.
Design: Prospective, open-label, randomised, controlled, multicentre reference device accuracy analysis.
Methods: A GAT and a modified surface GAT prism measured IOP on 243 unique eyes. The study design and methodology complied with International Standard Organization (ISO) tonometer evaluation guidelines, except the inclusion of thin (<500 µm) and thick (>600 µm) corneas. All eyes were randomised to IOP measurement by one of five standard Goldmann prisms and five modified prisms. Pressures were measured by six investigators, two times with each prism for a total of 1936 IOP measurements. Analysis included a multiple linear regression including CCT and CH correlation.
Results: The difference in IOP measurements of the standard and modified Goldmann prisms correlated well to CCT particularly in thin (<500 µm) and thick (>600 µm) corneas (R=0.404, p=0.007). Corneal hysteresis (CH) also significantly correlated to the difference in prism measurements (R=0.125, p=0.039). There was no significant overall mean IOP bias between the two prisms (+0.43 mm Hg in modified, p=0.19).
Discussion: The paired IOP measurement difference between GAT and a modified surface Goldmann replacement prism indicated a statistically significant correlation to CCT and CH. A simple modified replacement prism for any Goldmann-type tonometer may significantly improve IOP measurement accuracy by minimising corneal biomechanical errors associated with CCT and CH.
Trial Registration Number: NCT02990169 and NCT02989909.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6900223 | PMC |
http://dx.doi.org/10.1136/bjophthalmol-2018-313470 | DOI Listing |
J Glaucoma
November 2024
Columbia University, Department of Ophthalmology, Vagelos College of Physicians and Surgeons, 630 W. 168th Street, New York, NY 10032.
Prcis: Community-based eye health screenings that incorporated fundus photography and optometric exams in a high-risk NYC population effectively identified a higher than average number of participants that required an in-office glaucoma evaluation.
Purpose: To report glaucoma screening rates and risk factors associated with referral for in-office glaucoma evaluation in the Manhattan Vision Screening and Follow-up Study (NYC-SIGHT).
Methods: In this 5-year, cluster-randomized clinical trial, eligible individuals aged 40 and older were recruited from affordable housing developments and senior centers.
Heliyon
January 2025
Faculty of Medical and Health Sciences, Tel Aviv University, Israel.
Objective: Pigmentary posterior vitreous detachment (PVD), referred to as "black PVD," is a rare entity describing PVD along with pigment dispersion in the vitreous. There are a few case reports describing pigmentary PVD, yet the association between pigmentary PVD and uveal and optic disc tumors was not described before. The aim of this study was to report the clinical features of patients with pigmentary PVD associated with these tumors.
View Article and Find Full Text PDFThis study characterizes a fluorescent -tdTomato neuronal reporter mouse line with strong labeling of axons throughout the optic nerve, of retinal ganglion cell (RGC) soma in the ganglion cell layer (GCL), and of RGC dendrites in the inner plexiform layer (IPL). The model facilitated assessment of RGC loss in models of degeneration and of RGC detection in mixed neural/glial cultures. The tdTomato signal showed strong overlap with >98% cells immunolabeled with RGC markers RBPMS or BRN3A, consistent with the ubiquitous presence of the vesicular glutamate transporter 2 (VGUT2, SLC17A6) in all RGC subtypes.
View Article and Find Full Text PDFEur J Ophthalmol
January 2025
Eye Clinic, Department of Surgical Sciences, University of Cagliari, Cagliari, Italy.
Purpose: To evaluate the incidence and to describe the characteristics of the intrableb pigmentation (IBP) following XEN63 implantation.
Methods: Retrospective case series of three eyes presenting a pigment dispersion in the filtering bleb after a XEN63 implantation for uncontrolled IOP. Demographic, clinical and imaging data were obtained from medical records.
Int J Mol Sci
December 2024
Department of Ophthalmology, University Medical Centre Ljubljana, Grablovičeva 46, 1000 Ljubljana, Slovenia.
In open-angle glaucoma, the increase in intraocular pressure (IOP) is caused by an increased resistance to aqueous humour outflow in the trabecular meshwork. Since genetic variability of matrix metalloproteinase (MMP) genes may influence extracellular matrix remodelling, we investigated their association with glaucoma risk and/or response to treatment. The retrospective part of the study included patients with primary open-angle glaucoma and ocular hypertension (OHT); in the prospective part of the study, newly diagnosed patients with POAG or OHT were randomised to receive either latanoprost or selective laser trabeculoplasty (SLT) as the initial treatment.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!