Introduction: We present our experience with hypothermic machine perfusion (HMP) versus cold storage (CS) in relation to kidney transplant outcomes.

Methods: Retrospective analysis of 33 consecutive HMP kidney transplant outcomes matched with those of 33 cold stored: delayed graft function (DGF), length of hospital stay (LOS), estimated glomerular filtration rate (eGFR), and patient and graft survival were compared. Renal Resistive Indexes (RIs) during HMP in relation to DGF were also analysed.

Results: In the HMP group, mean HMP time was 5.7 ± 3.9 hours with a mean cold ischaemic time (CIT) of 15 ± 5.6 versus 15.1 ± 5.3 hours in the CS group. DGF was lower in the HMP group (p=0.041), and donation after Circulatory Death (DCD) was a predictor for DGF (p<0.01). HMP decreased DGF in DCD grafts (p=0.036). Patient and graft survival were similar, but eGFR at 365 days was higher in the HMP cohort (p<0.001). RIs decreased during HMP (p<0.01); 2-hours RI ≥ 0.45 mmHg/mL/min predicted DGF in DCD kidneys (75% sensitivity, 80% specificity; area under the curve 0.78); 2-hours RI ≥ 0.2 mmHg/ml/min predicted DGF in DBD grafts (sensitivity 100%, specificity 91%; area under the curve 0.87).

Conclusion: HMP decreased DGF compared to CS, offering viability assessment pretransplant and improving one-year renal function of the grafts.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6354149PMC
http://dx.doi.org/10.1155/2019/7435248DOI Listing

Publication Analysis

Top Keywords

machine perfusion
8
cold storage
8
kidney transplant
8
hmp group
8
hmp
6
cold
5
cold pulsatile
4
pulsatile machine
4
perfusion versus
4
versus static
4

Similar Publications

Liver Transplantation after Ex Vivo normothermic machine preservation without re-cooling the graft: A clinical series from a single center.

Liver Transpl

January 2025

Abdominal Center Department, Istituto di Ricovero e Cura a Carattere Scientifico-Istituto Mediterraneo per i Trapianti e Terapie ad alta specializzazione (IRCCS ISMETT), University of Pittsburgh Medical Center Italy (UPMCI), Palermo, Italy.

View Article and Find Full Text PDF

Background: Cardiovascular diseases (CVDs) continue to be the world's greatest cause of death. To evaluate heart function and diagnose coronary artery disease (CAD), myocardial perfusion imaging (MPI) has become essential. Artificial intelligence (AI) methods have been incorporated into diagnostic methods such as MPI to improve patient outcomes in recent years.

View Article and Find Full Text PDF

UW supplementation with AP39 improves liver viability following static cold storage.

Sci Rep

January 2025

Center for Engineering in Medicine and Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA.

Static cold storage of donor livers at 4 °C incompletely arrests metabolism, ultimately leading to decreases in ATP levels, oxidative stress, cell death, and organ failure. Hydrogen Sulfide (HS) is an endogenously produced gas, previously demonstrated to reduce oxidative stress, reduce ATP depletion, and protect from ischemia and reperfusion injury. HS is difficult to administer due to its rapid release curve, resulting in cellular death at high concentrations.

View Article and Find Full Text PDF

Hypothermic oxygenated machine perfusion (HOPE) preconditions liver grafts before transplantation. While beneficial effects on patient outcomes were demonstrated, biomarkers for viability assessment during HOPE are scarce and lack validation. This study aims to validate the predictive potential of perfusate flavin mononucleotide (FMN) during HOPE to enable the implementation of FMN-based assessment into clinical routine and to identify safe organ acceptance thresholds.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!