A rare postoperative complication of aortic root replacement is pseudoaneurysm formation. Surgical repair may be rather challenging particularly in patients who are elder and with significant comorbidities. Endovascular approach may also be technically demanding, given the high blood velocity and the anatomical challenges of the area of the aortic root and the ascending aorta. We would like to describe a case of an 85-year-old patient with history of prosthetic graft aortic root replacement who had been developed a 7-cm pseudoaneurysm with sternotomy diastasis and extension in the subcutaneous tissue, 7 years after the initial operation. Given the comorbidities, open repair was not considered a valid option and successful endovascular repair with the use of a ventricular septal occluder plug followed. One-year follow-up confirmed satisfactory exclusion of the pseudoaneurysm with no migration of the endovascular device and no other complication. This is one of the rare cases on endovascular repair of an ascending aorta postoperative pseudoaneurysm.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6376348 | PMC |
http://dx.doi.org/10.1556/1646.10.2018.41 | DOI Listing |
J Cardiothorac Surg
January 2025
Cerrahpasa Medical Faculty, Department of Cardiovascular Surgery, Istanbul University-Cerrahpasa, Istanbul, Turkey.
Objectives: Despite the advances in medicine, aortic dissection remains a cardiac surgery emergency with high mortality and morbidity rates. This study examined the effects of the Glue + Felt technique, which uses biological glue and felt to repair the proximal anastomotic site, on the outcomes of patients with acute type A aortic dissection.
Methods: A total of 108 patients who underwent surgery for acute type A aortic dissection at our clinic between 2007 and 2020 were included in the study.
Eur Radiol
January 2025
Department of Radiology, University of Groningen, University Medical Center of Groningen, Groningen, The Netherlands.
Objective: To evaluate the repeatability of AI-based automatic measurement of vertebral and cardiovascular markers on low-dose chest CT.
Methods: We included participants of the population-based Imaging in Lifelines (ImaLife) study with low-dose chest CT at baseline and 3-4 month follow-up. An AI system (AI-Rad Companion chest CT prototype) performed automatic segmentation and quantification of vertebral height and density, aortic diameters, heart volume (cardiac chambers plus pericardial fat), and coronary artery calcium volume (CACV).
Pediatr Transplant
February 2025
The Heart Institute, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio, USA.
Background: Partial heart transplantation (PHT) is a novel procedure for children in need of a growing valve replacement option. One challenge is identifying suitable donor valves. Semilunar heart valves from patients receiving a retransplant may be a source, however their functionality and growth potential especially at the time of retransplant are unknown.
View Article and Find Full Text PDFBackground And Aims: An arterial aneurysm is characterized by a localized expansion of a blood vessel relative to its original dimensions. Specifically, an abdominal aortic aneurysm (AAA) is identified as an aortic diameter measuring at least one and a half times the standard diameter at the renal artery level, approximately equivalent to 2.0 cm.
View Article and Find Full Text PDFEchocardiography
January 2025
Radiology Department, Hacettepe University Faculty of Medicine, Ankara, Turkey.
Left images: Top: (A) Echocardiography shows a dilated pulmonary artery, large aortopulmonary window (dotted line), and abnormally positioned aortic arch. (B) MIP image reveals superior RV, inferior LV, and elongated arch vessels (arrows). Bottom: MinIP shows a thin left main bronchus and non-aerated RML (asterisk).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!