A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Improving Localization and Speech Reception in Noise for Bilateral Cochlear Implant Recipients. | LitMetric

Improving Localization and Speech Reception in Noise for Bilateral Cochlear Implant Recipients.

Trends Hear

1 Research and Technology Labs, Cochlear Ltd., Centennial, CO, USA.

Published: November 2019

This study looked at different methods to preserve interaural level difference (ILD) cues for bilateral cochlear implant (BiCI) recipients. One possible distortion to ILD is from automatic gain control (AGC). Localization accuracy of BiCI recipients using default versus increased AGC threshold and linked AGCs versus independent AGCs was examined. In addition, speech reception in noise was assessed using linked versus independent AGCs and enabling and disabling Autosensitivity™ Control. Subjective information via a diary and questionnaire was also collected about maps with linked and independent AGCs during a take-home experience. Localization accuracy improved in the increased AGC threshold and the linked AGCs conditions. Increasing the AGC threshold resulted in a 4° improvement in root mean square error averaged across all speaker locations. Using linked AGCs, BiCI participants experienced an 8° improvement for all speaker locations and a 19° improvement at the speaker location most affected by the AGC. Speech reception threshold in noise improved by an average of 2.5 dB when using linked AGCs versus independent AGCs. In addition, the effect of linked AGCs on speech in noise was compared with that of Autosensitivity™ Control. The Speech, Spatial, and Qualities of Hearing Scale-12 question comparative survey showed an improvement when using maps with linked AGCs. These findings support the hypothesis that ILD cues may be preserved by increasing the AGC threshold or linking AGCs.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6391546PMC
http://dx.doi.org/10.1177/2331216519831492DOI Listing

Publication Analysis

Top Keywords

linked agcs
24
agc threshold
16
independent agcs
16
speech reception
12
versus independent
12
agcs
11
reception noise
8
bilateral cochlear
8
cochlear implant
8
ild cues
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!